IMG-120T
Industrial 2-port RS422/485 Modbus Gateway
Serial Interface
• Two RS422/485 ports with 5-contact terminal block
• Cost effective for RS422/RS485 to Fast Ethernet 10/100BASE-
TX application
• Supports 4-wire RS422 or 2-wire RS485 with 5-contact terminal
block
• 300bps~115200bps baud rate and non-blocking communication
Ethernet Interface
• Complies with IEEE 802.3, IEEE 802.3u 10/100BASE-TX
standard
• Supports 10/100BASE-TX RJ45 port with distance up to 100m
Management Function
Economical Solution for Industrial Modbus TCP/RTU/ASCII Network Integration
• Built-in IP-based Web interface and telnet interface for remote
PLANET has added the Industrial Modbus TCP/IP Protocol to its IMG-120T Industrial-
management
level 2-port RS422/485 Modbus Gateway, an industrial management level product that
• Software Protocol supports Modbus TCP, Modbus RTU,
comes with SCADA/HMI system and other data acquisition systems on the factory floor. Modbus ASCII, IP, ARP, DHCP and DNS
Moreover, an industrial IT SNMP network can be upgraded to an Industrial automation • Supports RTU Master, RTU Slave, ASCII Master, and ASCII
Modbus TCP/IP network without any difficulty and extra expense. The IMG-120T offers Slave modes via management interface
a flexible network connectivity solution for industrial automation environment. PLANET • Master mode supports 32 slave TCP connection requests
IMG-120T is a conversion bridge between Modbus TCP/IP Protocol and Modbus RTU/ • Slave mode supports 16 TCP master connections
ASCII Protocol. It features a wide operating temperature range from -40 to 75 degrees C • Supports IP address and MAC address filtering function
and a compact but rugged IP40 metal housing. • PLANET Modbus Gateway utility for finding client device on
the network and related IP subnet address setting, to reset to
factory default function
• PLANET Smart Discovery utility automatically finds the client
devices on the network
• Firmware upgrade/configuration backup and restore via HTTP
protocol
Hardware
• LED indicators for system, network and RS422/485 port
diagnostics
• DIP switch on the upper panel for resetting to factory default
• Wall-mount kit
The Conversion Bridge that Makes Communications Convenient Industrial Case and Installation
As the conversion bridge, the IMG-120T communicates well between any industrial • Wallmount-type IP40 metal case
equipment with the Modbus RTU/ASCII Protocol and the administrator workstation that • The 2-contact terminal block connector on the top panel of
runs the Modbus TCP/IP Protocol. The RS422/485 serial interface of the IMG-120T Industrial Modbus Gateway is used for DC power input (9-48V)
provides the Modbus RTU/ASCII operation mode and various baud rate options to meet • -40 to 75 degrees C operating temperature
the demand of integration between the Modbus TCP/IP Protocol, Modbus RTU Master/
Slave Protocol and Modbus ASCII Master/Slave Protocol.
1
Page2
IMG-120T
Industrial Modbus Environment
Modbus TCP/IP Ethernet IMG-120T RS422/RS485
V+
Reset
10/100TX
Modbus TCP/IP Industrial Serial CableModbus IndustrialGateway
RS422/RS485
10/100TX UTP TX1 RX1 EquipmentTX2 RX2
PWR LNK/
ACT
IMG-120T
COM
Workstation 1 COM2
with SCADA
RTU ASCII RTU ASCII
Slave Slave Master Master
16 TCP Masters 32 TCP Slaves
The advantage of having the IMG-120T is to assist users to build an industrial environment between the Modbus TCP/IP Protocol and the Modbus RTU/
ASCII Protocol easily, thus offering an application solution to the industrial control equipment without Ethernet ports. Thus, the industrial control equipment
can only control through an industrial PC workstation or industrial control panel.
In addition, the effective integration of Modbus Ethernet devices, Modbus serial equipment or multi Modbus master/slave in an industrial hybrid network brings
the following:
■ Master mode supports up to 32 slave TCP connection requests
■ Slave mode supports up to 16 TCP master connections
Remote Management
The IMG-120T makes the connected industrial Modbus RTU/ASCII equipment become IP-based facilities and is able to connect to the Modbus TCP/IP
network via its R422/485 serial interface and 10/100BASE-TX RJ45 Ethernet port. It provides a remote web management and telnet Interface for efficient
remote network management. The IMG-120T also provides PLANET Modbus Gateway utility tool and supports PLANET Smart Discovery utility to help
network administrator to easily get the current IP subnet address information or change the IP subnet address setting of the IMG-120T.
V+
Reset
10/100TX
Modbus Gateway Utility TCP/IP IndustrialModbus Gateway
TX1 RX1
TX2 RX2
PWR LNK/
ACT
IMG-120T
COM1
COM2
IMG-120T
Modbus Gateway
Web Browser Remote Management
Modbus Serial Port State Monitoring
The IMG-120T shows the details of the total bytes transmitted and received on the RS422/485 serial interface, and the detailed total number of frames
transmitted and received on the remote web/telnet management interface. This function allows network administrator to check the status and statistics of the
IMG-120T via the single RS422/485 serial interface.
Stable Performance in Hardened Environment Design
The IMG-120T provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors
or in curb-side traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the IMG-120T to be placed in almost any difficult
environment.
The IMG-120T is equipped with a compact IP40-rated metal case that allows wall mounting for efficient use of cabinet space. The IMG-120T also provides an
integrated power supply source with wide-ranging voltages (9 to 48V DC) ideally suitable for worldwide operation with high availability applications.
2
T+/D+
GND
R+
T+/D+
GND
R+
T+/D+
GND
R+
T+/D+
GND
R+
Page3
IMG-120T
Applications
RTU/ASCII Master to Multi Modbus TCP/IP Slaves
The IMG-120T can act as a bridge between the industrial RTU/ASCII master equipment and the multi-industrial TCP/IP slave equipment in a Modbus TCP/IP
networking environment to control multi-industrial TCP/IP slave equipment via the industrial RTU/ASCII master equipment.
RTU/ASCII Master to Multi Modbus TCP/IP Slaves
V+
Reset
10/100TX
Industrial
M IMG-120Todbus Gateway
RS485
TX1 RX1 Modbus Gateway
TX2 RX2
PWR LNK/
ACT
IMG-120T
COM1
COM2
HMI
RTU/ASCII Master
Modbus TCP/IP
Slave Devices
DCS DCS
100BASE-TX UTP
RS485 RS485
Multi Modbus TCP/IP Master to RTU/ASCII Slaves
The IMG-120T can operate as a bridge between the multi-industrial TCP/IP master equipment and the industrial RTU/ASCII slave equipment in a Modbus
TCP/IP networking environment to control the industrial RTU/ASCII slave equipment via the multi-industrial TCP/IP master equipment.
Multi Modbus TCP/IP Master to RTU/ASCII Slaves
Host Computer Modbus TCP
Master Devices
Modbus TCP Master PLC
V+ V+
Reset Reset
10/100TX 10/100TX
Industrial IMG-120T IndustrialM M IMG-120Todbus Gate ow da by us Gateway
TX1 RX1 Modbus Gateway TX1 RX1 Modbus Gateway
TX2 RX2 TX2 RX2
PWR LNK/ PWR LNK/
ACT ACT
IMG-120T IMG-120T
COM1 COM1
COM2 COM2
RS485 RS485 RS485
RS485 Modbus/RTU
Modbus/ASCII
Slave Devices
Flow Meters (Drive) Loop Controller, Power Measurement
(up to 32 Devices)
100BASE-TX UTP
RS485 RS485
3
T+/D+
GND
R+
T+/D+
GND
R+
T+/D+
GND
R+
T+/D+
GND
R+
T+/D+
GND
R+
T+/D+
GND
R+
Page4
IMG-120T
Specifications
Product IMG-120T
Serial Port
Interface RS422/RS485 x 2
Connector 10-contact terminal block for RS422/RS485
Surge Protection 1KV
Baud Rate (Data Rate) 300bps to 115200bps
Data Bits 7, 8
Parity Type Odd, Even, None, Space, Mark
Stop Bit 1, 2
Flow Control H/W, None
Signals RS422: Tx+, Tx-, GND, Rx+, Rx-RS485: Data A (+), GND, Data B (-)
Distance RS422/RS485 for 20m transfer distance
RTU Master/RTU Slave/ASCII Master/ASCII Slave
Operation Mode Master mode: Supports up to 32 slave TCP connection requests
Slave mode: Supports up to 16 TCP master connection requests
Fast Ethernet Port
IEEE 802.3 10BASE-T standard
Standard IEEE 802.3u 100BASE-TX standard
IEEE 802.3x Full-duplex flow control
Connector RJ45
Distance 100 meters
Hardware
Copper Port 10/100BASE-TX RJ45 TP x1, auto-MDI/MDI-X, auto-negotiation
Serial Port RS422/RS485 x 2
DIP Switch Reset system to factory default
System: Power x 1
LED Indicators 10/100BASE-TX Port: Link/Active x 1
RS422/RS485 Serial Port: TX (Transmit) x 2, RX (Receive) x 2
Remote Web Management
Management Remote Telnet ManagementPLANET Modbus Gateway Utility
PLANET Smart Discovery Utility
RTU Master
Operation Mode RTU SlaveASCII Master
ASCII Slave
Dimension (W x D x H) 69 x 100 x 22 mm
Weight 238g
Power Input Connector 2-contact terminal block connector DC power (9-48V) *
Power Consumption 1.25W@9V (max.)
Installation Wall-mount kit
Mechanical Metal
Standards Conformance
IEEE 802.3 10BASE-T standard
Standards Compliance IEEE 802.3u 100BASE-TX standardIEEE 802.3x Full-duplex flow control
EIA/TIA RS422/485
Regulatory Compliance FCC Part 15 Class B, CE
IEC60068-2-32 (free fall)
Stability Testing IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
Environment
Temperature Operating: -40~75 degrees CStorage: -40~75 degrees C
Humidity Operating: 5~95% (non-condensing)Storage: 5~95% (non-condensing)
*: Please follow the DC power input symbol from the front panel of the IMG-120T -- insert positive DC power wire into V+, and negative DC power wire
into V-. Otherwise, it will damage the device.
4
Page5
IMG-120T
Ordering Information
IMG-120T Industrial 2-port RS422/485 Modbus Gateway
Related Products
IMG-110T Industrial 1-port RS422/485 Modbus Gateway
ICS-100 RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter
ICS-2100 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
PWR-40-24 / PWR-60-24 / PWR-75-24 DC Single Output Industrial DIN Rail Power Supply Units
PLANET Technology Corporation
11F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, IMG-120T
Taiwan (R.O.C.)
PLANET reserves the right to change specifications without prior notice. All brand names and trademarks are property of
Tel: 886-2-2219-9518 Fax: 886-2-2219-9528 their respective owners. Copyright © 2017 PLANET Technology Corp. All rights reserved.
Email: sales@planet.com.tw www.planet.com.tw
5