1/6ページ
Download(1.3Mb)
FLAG DROP TYPE FAULT INDICATOR TK TYPE
Product Catalog
Document Information
| Document Title | FLAG DROP TYPE FAULT INDICATOR TK TYPE |
|---|---|
| Document Type | Product Catalog |
| File size | 1.3Mb |
| Category | |
| Company | FUJI ELECTRIC INDUSTRY CO., LTD. (Documents List) |
Documents related to this company
Document Contents
Page1
FLAG DROP TYPE FAULT INDICATOR
TK TYPE
FEATURES
■The built-in switching contacts are applicable to the output from 4 circuits with different functions. The use of this
indicator can save the auxiliary relays.
■The versions for voltage and current are so designed as to prevent wrong insertion.
■The inside element is a plug-in type, which facilitates maintenance and checks (or replacement).
■A no-voltage one-shot pulse contact can be incorporated.
■A variety of combinations of output contacts are available.
SPECIFICATIONS (RATINGS, PERFORMANCE)
Specification Type TK
Rated insulation voltage (Ui) 250V
Operating temperature –20 to 50°C
Operating humidity 45 to 85%
Storing temperature –20 to 60°C
Shape Embedded in switchboard, with 1 element
Panel thickness 1 to 3.2㎜
Inclination of applicable panel 30 degrees max. from vertical plane
Surface cover color JIS (Munsell color) code: N1.5, 7.5BG4 / 1.5 (N1.5 only for MK type)
Weight Approx. 430g
B55
Page2
PILOT LAMP & INDICATOR
HOW TO ORDER Select from the following product coding.
●Standard spec
TKL 121 - DC110 B R
① ② ④ ⑤ ⑥
●Power monitor spec (Normally exciting type)
TKL 12B0 TX - DC110 B R
① ② ③ ④ ⑤ ⑥
No. Item Code Detail Note
TKL For voltage ̶
① Basic type
TKH For current ̶
② Contact arrangement Contact arrangement (see list of contact arrangement)
̶
Blank Standard coil spec ̶
For TKH (1.0A) type only.
W Double coil spec (1.0A DC only) It is special type.
③ Spec
Internal element fixed type
X ̶
With varistor
TX For power source monitoring
̶
DC024 24V DC Coil resistance:250Ω
DC030 30V DC Coil resistance:320Ω
DC048 48V DC Coil resistance:1,170Ω
DC110 100 / 110V DC Coil resistance:4,700Ω
L DC125 125V DC Coil resistance:5,200Ω
DC220 200 / 220V DC Coil resistance:18,600Ω
④ Coil spec AC110 100 / 110V AC Coil resistance:4,700Ω
AC220 200 / 220V AC Coil resistance:18,600Ω
AC240 240 AC Coil resistance:20,600Ω
DC0.5A 0.5A DC Coil resistance:3.0Ω
DC0.7A 0.7A DC Coil resistance:2.0Ω
H
DC1A 1.0A DC Coil resistance:0.75Ω
DC2A 2.0A DC Coil resistance:0.35Ω
̶
B Black(N1.5)
⑤ Front cover color
4 / 1.5 7.5BG4 / 1.5 ̶
Flag color ̶
Blank(O)* Orange(Standard color)
⑥ (when power loses)
R Red(Special color) ̶
B56
D ELECTRONIC DEVICES C CONNECTING DEVICES B PILOT LAMP & INDICATOR A SWITCH
Page3
FLAG DROP TYPE FAULT INDICATOR
TK TYPE
TK TYPE
Card
t=0.8mm max.
Fitting (screwed from surface)
Card holder
Display window
Reset button
t=1 to 3.2mm
Faston tub #250 series
●Mounting hole size
Pitch (Min.)
40 40
Normal condition (Black) Fault condition (Orange) Continuous fault condition (Stripe pattern)
●Operation
→ : Manual resetting
→ : Automatic resetting
34.5 ± 0.5 34.5 ± 0.5
SPECIFICATIONS (RATINGS, PERFORMANCE)
Item Type Voltage operation type Current operation type
Rating Continuous at rated value
Coil temperature rise of 55°C max. in the maximum
Overload tolerance 30S at 500%
operating range (1.3 times the rating for 3 hours)
Minimum operating value 70% of rating 80% of rating
Contact current-carrying capacity 3A 110V DC
R load: 0.4A (110V DC) 0.2A (220V DC)
Contact breaking capacity L load: 0.1A (110V DC) 0.03A (220V DC)
L / R = 12ms
Normal type a1: 60±15ms 75ms or less Normal type a1: 50±15ms 75ms or less
W type a2: 40±10ms 50ms or less Rising-edge W type a2: 20±10ms 45ms or less Rising-edge
Operating time X type a3: 90±10ms 100ms or less delay from X type a3: 80±10ms 90ms or less delay from
IN input to IN input to
(at rated voltage and current) a1: 60±15ms 75ms or less contact a1: 50±15ms 75ms or less contact
TX type a2: 40±10ms 100ms or less output TX type a2: 20±10ms 100ms or less output
a3: 90±10ms 100ms or less a3: 80±10ms 90ms or less
Pulse contact time 50 to 100ms
In normal use: N1.5 (Black)
Display panel color
At failure: 2.5YR6/13 (Orange)
(Munsell color)
When failure persists: N1.5 and 2.5YR6/13 stripes
Insulation resistance 50MΩ or more (500V DC)
Whole terminals and contact points: 2,000V AC / 1 min.
Between electric circuit and contact: 2,000V AC / 1 min.
Withstand voltage Between contact circuits: 2,000V AC / 1 min.
Between open contacts: 1,000V AC / 1 min.
Between open contacts: 3,000V (1.2 / 50µs)
Lightning impulse
Between live parts and live part to assembly mounting panel: 4,500V (1.2 / 50µs)
Service life 10,000 times or more. each for electrical and mechanical life
Vibration resistance Frequency: 16.7 Hz Double amplitude: 4mm 10 min. in each of 3 axial directions
Shock resistance Shock resistance: 30G or more Each 2 axial directions: 2 times each
B57
80
65 ± 0.3
Page4
PILOT LAMP & INDICATOR
CONTACT ARRANGEMENT DIAGRAM
(1)TK 100 Ry (9)TK 010 Ry ( 17)TK 12B0 Ry
+9 1 +9 1 +9 5 3 1
a1 a2 b2 b2 a1
30 30 30 ´
-10 2 -10 2 -10 6 4 2
(2)TK 200 Ry (10)TK 011
Ry (18)TK 12B1
Ry
+9 3 1 +9 3 1 +9 7 5 3 1
a1 a1 a2 a3 b2 b2 a1 a3
30 ´ 30 30 ´
-10 4 2 -10 4 2 -10 8 6 4 2
(3)TK 110 Ry (11)TK 021 Ry (19)TK 1AB1 Ry
+9 3 1 +9 5 3 1 +9 7 5 3 1
a1 a2 a2 a3 b2 a2 a1 a3
30 30 ´ 30
-10 4 2 -10 6 4 2 -10 8 6 4 2
(4)TK 111 Ry (12)TK 020 Ry (20)TK 0AB0 Ry
+9 5 3 1 +9 3 1 +9 3 1
a2 a1 a3 a2 a2 b2 a2
30 30 ´ 30
-10 6 4 2 -10 4 2 -10 4 2
(13)TK 001 (21)TK AB00
Ry
(5) Ry
TK 000 Ry
+9 +9 1
+9 3 1
a3
b1 a1
30 30
30
-10 2
-10 4 2
Ry
(14)TK 030 (22)TK A2B00 Ry
(6)TK 101 Ry
+9 5 3 1 +9 5 3 1
+9 3 1
a2
a1 a3 ´ a2´ a2 b1 b1 a1
30 30 ´
30
-10 6 4 2 -10 6 4 2
-10 4 2
(7)TK 120 Ry (15)TK 210 Ry (23)TK 02C0 Ry
+9 5 3 1 +9 5 3 1 +9 5 1
● ●
a2 a2 a1 a2 a1 a1 a2
30 ´ a2
30 30 ´
b2´ b2
-10 6 4 2 -10 6 4 2 -10 8 6 4 2
(8)TK 121 (16)TK 1AB0 (24)TK 2C00
Ry Ry Ry
+9 7 5 3 1 +9 5 3 1 +9 5 1
● ●
a2 a2 a1 a3 b2 a2 a1 a1´ a1
30 ´ 30 30
b1´ b1
-10 8 6 4 2 -10 6 4 2 -10 8 6 4 2
B58
D ELECTRONIC DEVICES C CONNECTING DEVICES B PILOT LAMP & INDICATOR A SWITCH
Page5
FLAG DROP TYPE FAULT INDICATOR
TK TYPE
LIST OF FUNCTIONS
Input rating Output contact
Contact which Contact which One-shot
Model for Current interlocked interlocked pulse
No. each contact Voltage
element with flag with coil contact
configuration element
(TKH)
(TKL) a1 ◯ b1 ◯ a2 ◯ b2 ◯
(TKH···W) a3 ◯
◯ ◯ ◯ ◯ ◯
1 TK 100 ◯ ◯ a1×1 ― ―
2 TK 200 ◯ ◯ a1×2 ― ―
3 TK 110 ◯ ◯ a1×1 a2×1 ―
4 TK 111 ◯ ◯ a1×1 a2×1 a3×1
5 TK 000 ◯ ◯ ― ― ―
6 TK 101 ◯ ◯ a1×1 ― a3×1
7 TK 120 ◯ ◯ a1×1 a2×1 ―
8 TK 121 ◯ ◯ a1×1 a2×2 a3×1
9 TK 010 ◯ ◯ ― a2×1 ―
10 TK 011 ◯ ◯ ― a2×1 a3×1
11 TK 021 ◯ ◯ ― a2×2 a3×1
12 TK 020 ◯ ◯ ― a2×2 ―
13 TK 001 ◯ ◯ ― ― a3×1
14 TK 030 ◯ ◯ ― a2×3 ―
15 TK 210 ◯ ◯ a1×2 a2×1 ―
16 TK 1AB0 ◯ ◯ a1×1 a2×1, b2×1 ―
17 TK 12B0 ◯ ◯ a1×1 b2×2 ―
18 TK 12B1 ◯ ◯ a1×1 b2×2 a3×1
19 TK 1AB1 ◯ ◯ a1×1 a2×1, b2×1 a3×1
20 TK 0AB0 ◯ ◯ ― a2×1, b2×1 ―
21 TK AB00 ◯ ◯ a1×1, b1×1 ― ―
22 TK A2B00 ◯ ◯ a1×1, b1×2 ― ―
23 TK 02C0 ◯ ◯ ― c×2 ―
24 TK 2C00 ◯ ◯ c×2 ― ―
1. For the above , specify L for voltage or H for current.
2. Please ask us when you need other contact type than the aboves.
B59
Page6
PILOT LAMP & INDICATOR
ACCESSORY
Element extraction tool
•TK extraction tool HOW TO REMOVE THE INTERNAL ELEMENT
Extraction for the cover
Extract the cover Drawing the inside element
Extract for the element
Plate thickness t = 1.2mm
OPERATIONAL INTRODUCTION
●When the failure detection contact of the outside protective relay is closed, the operating coil is excited, and the
display panel falls off. The display window changes from black (N1.5) indicating the normal status to orange
(2.5YR6/13) indicating the failure status.
●When the reset button is pressed, the display panel will be returned to blank. If the failure is instantaneous and no
input is provided, the display window will return to the black display in the normal status. If the failure persists,
however, the coil receives input and a pattern of stripes of orange and black is displayed indicating that the failure
persists. Once the failure is rectified, the display will automatically return to the black display in the normal status.
●Max. 4 contacts are available.
Contacts interlocked with the display panel may be taken for a maximum of 2 circuits. Those interlocked with the
coil may be taken for a maximum of 3 circuits. One-shot pulse contacts interlocked with the display panel may be
taken for a maximum of 2 circuits. Each circuit is provided with contacts a and b.
●The one-shot pulse contacts output pulses (50 to 70 ms) at the initial operation only.
●Standard specication
Ry Coil voltage
+9 7 5 3 1 Black
Orange
a2 a2 a1 a3 Stripe pattern
30 ´ Contact which interlocked with flag
(a contact) a1
Contact which interlocked with coil
(a contact) a2・a2
One-shot pulse a3 ´
-10 8 6 4 2
Manual reset operation
1: All the coils for voltage type are added a
counter induced-voltage absorption device.
●Power monitor specication (Normally excited type)
Coil voltage
Black
Orange / Red
Contact which interlocked with flag
~ Remark ~ (a contact) a
Contact which interlocked with coil
The coil is normally in excited status (black). Upon occurrence (b contact) b
of a fault, the coil excitation is released, resulting in drop of the
target (red). No continuing fault indicating function is provided. Manual reset operation
B60
Contact Display color Contact Display color
→→
→→
D ELECTRONIC DEVICES C CONNECTING DEVICES B PILOT LAMP & INDICATOR A SWITCH