FLAG DROP TYPE FAULT INDICATOR TK TYPE

Product Catalog

Document Information

Document Title FLAG DROP TYPE FAULT INDICATOR TK TYPE
Document Type Product Catalog
File size 1.3Mb
Category
Company FUJI ELECTRIC INDUSTRY CO., LTD. (Documents List)

Documents related to this company

この企業の関連カタログの表紙
Flag Drop Type Fault Indicator ZK Type
Product Catalog

FUJI ELECTRIC INDUSTRY CO., LTD.

この企業の関連カタログの表紙
DISCREPANCY SWITCH BHL TYPE
Product Catalog

FUJI ELECTRIC INDUSTRY CO., LTD.

この企業の関連カタログの表紙
SEMAPHORE INDICATOR SPSR TYPE, SPSL TYPE
Product Catalog

FUJI ELECTRIC INDUSTRY CO., LTD.

Document Contents

Page1

FLAG DROP TYPE FAULT INDICATOR TK TYPE FEATURES ■The built-in switching contacts are applicable to the output from 4 circuits with different functions. The use of this indicator can save the auxiliary relays. ■The versions for voltage and current are so designed as to prevent wrong insertion. ■The inside element is a plug-in type, which facilitates maintenance and checks (or replacement). ■A no-voltage one-shot pulse contact can be incorporated. ■A variety of combinations of output contacts are available. SPECIFICATIONS (RATINGS, PERFORMANCE) Specification Type TK Rated insulation voltage (Ui) 250V Operating temperature –20 to 50°C Operating humidity 45 to 85% Storing temperature –20 to 60°C Shape Embedded in switchboard, with 1 element Panel thickness 1 to 3.2㎜ Inclination of applicable panel 30 degrees max. from vertical plane Surface cover color JIS (Munsell color) code: N1.5, 7.5BG4 / 1.5 (N1.5 only for MK type) Weight Approx. 430g B55
Page2

PILOT LAMP & INDICATOR HOW TO ORDER Select from the following product coding. ●Standard spec TKL 121 - DC110 B R ① ② ④ ⑤ ⑥ ●Power monitor spec (Normally exciting type) TKL 12B0 TX - DC110 B R ① ② ③ ④ ⑤ ⑥ No. Item Code Detail Note TKL For voltage ̶ ① Basic type TKH For current ̶ ② Contact arrangement Contact arrangement (see list of contact arrangement) ̶ Blank Standard coil spec ̶ For TKH (1.0A) type only. W Double coil spec (1.0A DC only) It is special type. ③ Spec Internal element fixed type X ̶ With varistor TX For power source monitoring ̶ DC024 24V DC Coil resistance:250Ω DC030 30V DC Coil resistance:320Ω DC048 48V DC Coil resistance:1,170Ω DC110 100 / 110V DC Coil resistance:4,700Ω L DC125 125V DC Coil resistance:5,200Ω DC220 200 / 220V DC Coil resistance:18,600Ω ④ Coil spec AC110 100 / 110V AC Coil resistance:4,700Ω AC220 200 / 220V AC Coil resistance:18,600Ω AC240 240 AC Coil resistance:20,600Ω DC0.5A 0.5A DC Coil resistance:3.0Ω DC0.7A 0.7A DC Coil resistance:2.0Ω H DC1A 1.0A DC Coil resistance:0.75Ω DC2A 2.0A DC Coil resistance:0.35Ω ̶ B Black(N1.5) ⑤ Front cover color 4 / 1.5 7.5BG4 / 1.5 ̶ Flag color ̶ Blank(O)* Orange(Standard color) ⑥ (when power loses) R Red(Special color) ̶ B56 D ELECTRONIC DEVICES C CONNECTING DEVICES B PILOT LAMP & INDICATOR A SWITCH
Page3

FLAG DROP TYPE FAULT INDICATOR TK TYPE TK TYPE Card t=0.8mm max. Fitting (screwed from surface) Card holder Display window Reset button t=1 to 3.2mm Faston tub #250 series ●Mounting hole size Pitch (Min.) 40 40 Normal condition (Black) Fault condition (Orange) Continuous fault condition (Stripe pattern) ●Operation → : Manual resetting → : Automatic resetting 34.5 ± 0.5 34.5 ± 0.5 SPECIFICATIONS (RATINGS, PERFORMANCE) Item Type Voltage operation type Current operation type Rating Continuous at rated value Coil temperature rise of 55°C max. in the maximum Overload tolerance 30S at 500% operating range (1.3 times the rating for 3 hours) Minimum operating value 70% of rating 80% of rating Contact current-carrying capacity 3A 110V DC R load: 0.4A (110V DC) 0.2A (220V DC) Contact breaking capacity L load: 0.1A (110V DC) 0.03A (220V DC) L / R = 12ms Normal type a1: 60±15ms 75ms or less Normal type a1: 50±15ms 75ms or less W type a2: 40±10ms 50ms or less Rising-edge W type a2: 20±10ms 45ms or less Rising-edge Operating time X type a3: 90±10ms 100ms or less delay from X type a3: 80±10ms 90ms or less delay from IN input to IN input to (at rated voltage and current) a1: 60±15ms 75ms or less contact a1: 50±15ms 75ms or less contact TX type a2: 40±10ms 100ms or less output TX type a2: 20±10ms 100ms or less output a3: 90±10ms 100ms or less a3: 80±10ms 90ms or less Pulse contact time 50 to 100ms In normal use: N1.5 (Black) Display panel color At failure: 2.5YR6/13 (Orange) (Munsell color) When failure persists: N1.5 and 2.5YR6/13 stripes Insulation resistance 50MΩ or more (500V DC) Whole terminals and contact points: 2,000V AC / 1 min. Between electric circuit and contact: 2,000V AC / 1 min. Withstand voltage Between contact circuits: 2,000V AC / 1 min. Between open contacts: 1,000V AC / 1 min. Between open contacts: 3,000V (1.2 / 50µs) Lightning impulse Between live parts and live part to assembly mounting panel: 4,500V (1.2 / 50µs) Service life 10,000 times or more. each for electrical and mechanical life Vibration resistance Frequency: 16.7 Hz Double amplitude: 4mm 10 min. in each of 3 axial directions Shock resistance Shock resistance: 30G or more Each 2 axial directions: 2 times each B57 80 65 ± 0.3
Page4

PILOT LAMP & INDICATOR CONTACT ARRANGEMENT DIAGRAM (1)TK 100 Ry (9)TK 010 Ry ( 17)TK 12B0 Ry +9 1 +9 1 +9 5 3 1 a1 a2 b2 b2 a1 30 30 30 ´ -10 2 -10 2 -10 6 4 2 (2)TK 200 Ry (10)TK 011 Ry (18)TK 12B1 Ry +9 3 1 +9 3 1 +9 7 5 3 1 a1 a1 a2 a3 b2 b2 a1 a3 30 ´ 30 30 ´ -10 4 2 -10 4 2 -10 8 6 4 2 (3)TK 110 Ry (11)TK 021 Ry (19)TK 1AB1 Ry +9 3 1 +9 5 3 1 +9 7 5 3 1 a1 a2 a2 a3 b2 a2 a1 a3 30 30 ´ 30 -10 4 2 -10 6 4 2 -10 8 6 4 2 (4)TK 111 Ry (12)TK 020 Ry (20)TK 0AB0 Ry +9 5 3 1 +9 3 1 +9 3 1 a2 a1 a3 a2 a2 b2 a2 30 30 ´ 30 -10 6 4 2 -10 4 2 -10 4 2 (13)TK 001 (21)TK AB00 Ry (5) Ry TK 000 Ry +9 +9 1 +9 3 1 a3 b1 a1 30 30 30 -10 2 -10 4 2 Ry (14)TK 030 (22)TK A2B00 Ry (6)TK 101 Ry +9 5 3 1 +9 5 3 1 +9 3 1 a2 a1 a3 ´ a2´ a2 b1 b1 a1 30 30 ´ 30 -10 6 4 2 -10 6 4 2 -10 4 2 (7)TK 120 Ry (15)TK 210 Ry (23)TK 02C0 Ry +9 5 3 1 +9 5 3 1 +9 5 1 ● ● a2 a2 a1 a2 a1 a1 a2 30 ´ a2 30 30 ´ b2´ b2 -10 6 4 2 -10 6 4 2 -10 8 6 4 2 (8)TK 121 (16)TK 1AB0 (24)TK 2C00 Ry Ry Ry +9 7 5 3 1 +9 5 3 1 +9 5 1 ● ● a2 a2 a1 a3 b2 a2 a1 a1´ a1 30 ´ 30 30 b1´ b1 -10 8 6 4 2 -10 6 4 2 -10 8 6 4 2 B58 D ELECTRONIC DEVICES C CONNECTING DEVICES B PILOT LAMP & INDICATOR A SWITCH
Page5

FLAG DROP TYPE FAULT INDICATOR TK TYPE LIST OF FUNCTIONS Input rating Output contact Contact which Contact which One-shot Model for Current interlocked interlocked pulse No. each contact Voltage element with flag with coil contact configuration element (TKH) (TKL) a1 ◯ b1 ◯ a2 ◯ b2 ◯ (TKH···W) a3 ◯ ◯ ◯ ◯ ◯ ◯ 1 TK 100 ◯ ◯ a1×1 ― ― 2 TK 200 ◯ ◯ a1×2 ― ― 3 TK 110 ◯ ◯ a1×1 a2×1 ― 4 TK 111 ◯ ◯ a1×1 a2×1 a3×1 5 TK 000 ◯ ◯ ― ― ― 6 TK 101 ◯ ◯ a1×1 ― a3×1 7 TK 120 ◯ ◯ a1×1 a2×1 ― 8 TK 121 ◯ ◯ a1×1 a2×2 a3×1 9 TK 010 ◯ ◯ ― a2×1 ― 10 TK 011 ◯ ◯ ― a2×1 a3×1 11 TK 021 ◯ ◯ ― a2×2 a3×1 12 TK 020 ◯ ◯ ― a2×2 ― 13 TK 001 ◯ ◯ ― ― a3×1 14 TK 030 ◯ ◯ ― a2×3 ― 15 TK 210 ◯ ◯ a1×2 a2×1 ― 16 TK 1AB0 ◯ ◯ a1×1 a2×1, b2×1 ― 17 TK 12B0 ◯ ◯ a1×1 b2×2 ― 18 TK 12B1 ◯ ◯ a1×1 b2×2 a3×1 19 TK 1AB1 ◯ ◯ a1×1 a2×1, b2×1 a3×1 20 TK 0AB0 ◯ ◯ ― a2×1, b2×1 ― 21 TK AB00 ◯ ◯ a1×1, b1×1 ― ― 22 TK A2B00 ◯ ◯ a1×1, b1×2 ― ― 23 TK 02C0 ◯ ◯ ― c×2 ― 24 TK 2C00 ◯ ◯ c×2 ― ― 1. For the above , specify L for voltage or H for current. 2. Please ask us when you need other contact type than the aboves. B59
Page6

PILOT LAMP & INDICATOR ACCESSORY Element extraction tool •TK extraction tool HOW TO REMOVE THE INTERNAL ELEMENT Extraction for the cover Extract the cover Drawing the inside element Extract for the element Plate thickness t = 1.2mm OPERATIONAL INTRODUCTION ●When the failure detection contact of the outside protective relay is closed, the operating coil is excited, and the display panel falls off. The display window changes from black (N1.5) indicating the normal status to orange (2.5YR6/13) indicating the failure status. ●When the reset button is pressed, the display panel will be returned to blank. If the failure is instantaneous and no input is provided, the display window will return to the black display in the normal status. If the failure persists, however, the coil receives input and a pattern of stripes of orange and black is displayed indicating that the failure persists. Once the failure is rectified, the display will automatically return to the black display in the normal status. ●Max. 4 contacts are available. Contacts interlocked with the display panel may be taken for a maximum of 2 circuits. Those interlocked with the coil may be taken for a maximum of 3 circuits. One-shot pulse contacts interlocked with the display panel may be taken for a maximum of 2 circuits. Each circuit is provided with contacts a and b. ●The one-shot pulse contacts output pulses (50 to 70 ms) at the initial operation only. ●Standard specication Ry Coil voltage +9 7 5 3 1 Black Orange a2 a2 a1 a3 Stripe pattern 30 ´ Contact which interlocked with flag (a contact) a1 Contact which interlocked with coil (a contact) a2・a2 One-shot pulse a3 ´ -10 8 6 4 2 Manual reset operation 1: All the coils for voltage type are added a counter induced-voltage absorption device. ●Power monitor specication (Normally excited type) Coil voltage Black Orange / Red Contact which interlocked with flag ~ Remark ~ (a contact) a Contact which interlocked with coil The coil is normally in excited status (black). Upon occurrence (b contact) b of a fault, the coil excitation is released, resulting in drop of the target (red). No continuing fault indicating function is provided. Manual reset operation B60 Contact Display color Contact Display color →→ →→ D ELECTRONIC DEVICES C CONNECTING DEVICES B PILOT LAMP & INDICATOR A SWITCH