1/8ページ
カタログの表紙 カタログの表紙 カタログの表紙
カタログの表紙

このカタログをダウンロードして
すべてを見る

ダウンロード(1.1Mb)

Hycleen Des 30 - Security of drinking water

製品カタログ

Top grade drinking water is vital

Top grade drinking water is an essential prerequisite for a healthy life and economic prosperity since this key resource - sometimes also called "blue gold" - cannot be simply substituted by any other. However, various factors increasingly impair our water quality. Drinking water of high quality and free of pathogens is indispensable for a healthy life.

このカタログについて

ドキュメント名 Hycleen Des 30 - Security of drinking water
ドキュメント種別 製品カタログ
ファイルサイズ 1.1Mb
取り扱い企業 ジョージフィッシャー株式会社 (この企業の取り扱いカタログ一覧)

この企業の関連カタログ

この企業の関連カタログの表紙
Supplier Code - Sustainability in the supply chain
製品カタログ

ジョージフィッシャー株式会社

この企業の関連カタログの表紙
Stay in touch with your level - Non-contact radar level transmitter type 2290
製品カタログ

ジョージフィッシャー株式会社

この企業の関連カタログの表紙
Stainless Steel Inserts
製品カタログ

ジョージフィッシャー株式会社

このカタログの内容

Page1

Security of drinking water Hycleen Des 30 for an environmentally friendly, electroactivated disinfection with sodium hypochlorite
Page2

Top grade drinking water is vital Top grade drinking water is an essential prerequisite for a healthy life and economic prosperity since this key resource – sometimes also called “blue gold”- cannot be simply substituted by any other. However, various factors increasingly impair our water quality. Drinking water of high qual- ity and free of pathogens is indispensable for a healthy life. Biofilm – habitat for bacterial cells in drinking A question of hygiene and prevention water distribution In terms of hygiene and prevention high drinking water Together with the drinking water bacteria are distributed quality is particularly important in hospitals, rehabilita- to and in every home and form a so-called biofilm where- tion centres, retirement homes, nursing homes, resi- ever they find nourishment. Piping systems and valves in dential complexes, hotels, holiday resorts, sports facili- the domestic distribution lines provide them with ideal ties, spa baths, schools, daycare centres, administrative conditions. Long stagnation periods and water tempera- buildings, indoor event venues, military facilities and pe- tures ranging from 25 to 50°C contribute to a proliferation nal institutions. of bacteria such as Legionella and Pseudomonas, which On the other hand, maintenance of piping systems in do- may cause infections in immunocompromised individu- mestic distribution lines and periodic checks of the drink- als. ing water quality tend to be neglected, with grave effects; securing top-grade drinking water often proves difficult in large residential properties. However, in view of tight- ened legal regulations facility operators are pushed to take measures to ensure high drinking water quality to avoid complaints, negative publicity, loss of revenue or even criminal penalties. 2
Page3

Four steps for optimum drinking water hygiene Looped installation Only top grade products used in the installation Prevention • Hydraulic calibration of the entire installation • Protection from lime scale if necessary 01 • Periodic cold water flushing Risk assessment 04 02 Monitoring • Assessment of drinking • Temperature monitoring water quality based on • Drinking water sampling various indicators 03 Intervention • Thermal disinfection • Chemical disinfection The integral drinking water hygiene concept In order to ensure high-quality drinking water at any time, the cold water as well as the hot drinking water supply needs to be considered as one integral system. That is why, with newly-built or planned properties preventive measures should be considered to minimize disturbances during operation. For existing properties preventive measures, however, should be supplemented with intervention measures. Ideal solution for existing properties disinfection, on the other hand, are ideal in terms of The integral water hygiene concept comprises four areas: intervention. Prevention, monitoring, intervention and risk assessment. This approach to secure drinking water hygiene offers GF JRG provides the perfect solution: an environmentally numerous advantages especially for existing properties friendly, highly efficient electroactivated disinfection unit because their given condition can be considered when - the Hycleen Des 30. Many years of experience show that restoring high-quality drinking water. As refurbishments this unit also treats old installation materials with care are executed in stages, preventive measures can often and therefore proves to be ideal for existing properties. be carried out only occasionally, thermal or chemical 3
Page4

Hycleen Des 30 – the systematic disinfection unit The Hycleen Des 30 unit generates the required electroactivated disinfectant with natriumhypo- chlorit on site. Years of experience with regard to drinking water additives have set high and unique standards. Environmentally friendly disinfection using water and salt Water + salt + Electroactivated electricity disinfectant with Top grade drinking water natriumhypochlorit The systematic solution Hycleen Des 30 uses only softened drinking water and high-purity salt to produce its highly effective disinfectant which is characterized by high reliability, minimal by-products and the lowest corrosion potential. After inoculating the drinking water with the electroactivated disinfectant, the solution is neutralized down the drain within a short time keeping the environmental impact low. The Hycleen Des 30 unit offers facility operators key advantages when disinfecting their drinking water systems: • Highly effective disinfectant against bacteria – small amounts are sufficient (fully compliant with the minimization principle) • Depot effect in the entire drinking water installation system • Approved disinfectant under Drinking Water Ordinance Sect. 11 • Low risk application; easy to use • Low risk application – no transport/no storage of dangerous chemicals • No micro-biologically induced corrosion • No development of resistance in micro-organisms; biofilms are removed • Does not impair the lifetime of GF JRG products; years of experience • Environmentally friendly disinfectant • Cost-effective technique 4
Page5

System structure for drinking water disinfection Feed unit Flow meter with scaler Feed unit with shut-off Meters the flow rate. and check valves. Vent Voltage 230 V Propor- tioning pump Ion exchanger System separator Filter 5 µm Drain Drain Hycleen Des 30 Monitoring Contains a membrane reactor, A measuring unit can be used to which produces the electroactivated monitor the chlorine concentration disinfectant with natriumhypochlorit. and other parameters. Soft water with 0-4 °TH must be provided. The Hycleen Des 30 is the heart of the whole system and is automatically operated by a central con- trol. For its use on the domestic water inlet further peripheral devices such as system separator, ion exchanger, pre-filter, flow meter, proportioning pump and feed unit must be allowed for and ad- justed to the type of property. Uncomplicated system configuration The Hycleen Des 30 is the heart of the whole system The Hycleen Des 30 system comprises three tanks. and is automatically operated by a central control. For The tank with Calzid-Ex is used to automatically clean its use on the domestic water inlet further peripheral the reactor at intervals. The high-purity saline solution devices have to be allowed for and adjusted to the type is produced in the large tank whereas another of property. tank contains the disinfectant. 5
Page6

High efficiency, long life Numerous customers have used the electroactivated disinfectant with natriumhypochlorit for more than ten years and confirm its high efficiency against bacteria such as Legionella and Pseudomonas. Using the Hycleen Des 30 unit does not impair the lifetime of GF JRG materials - neither in cold nor in hot water lines. Drinking water hygiene is vital in these facilities • Hospitals and rehabilitation centres • Old people’s homes and nursing homes • Residential complexes, hotels and holiday resorts • Sports facilities • Spa baths • Schools and daycare centres • Administrative buildings • Indoor event venues • Military facilities • Penal institutions References GF JRG engineers faced special challenges when securing the drinking water quality in large existing properties such as shown in the references below. Residential village in Germany totalling 20 houses and a central water distribution Challenge: Only occasionally occupied and used properties resulting in long stagnation periods of drinking water. Hospital in Germany totalling 680 rooms Challenge: 20-year old drinking water distribution with various microbiological loads. Sports and Indoor Event venue St. Jakob in Basel Challenge: Greatly varying consumption rates of drinking water resulting in microbiological loads in the course of years. 6
Page7

Specifications The Hycleen Des 30 unit generates an natriumhypochlorit disinfectant on site that is highly effec- tive against germs, bacteria, biofilm, and viruses. Description Unit Value Production volume (neutral anolyte) l/h 30 Free chlorine in natriumhypochlorit (EN 901) mg/l < 200 Production volume NaOCl/NaOH l/h 20/20 Disinfectant type neutral anolyte or anolyte selectable Connection dimension disinfectant tanks DN 8 Drinking water inlet pressure bar 3 - 10 System pressure bar 1,8 Process adjuvant - high-purity saturated saline solution g/l 0 - 2,0 Operation Switch 4 Automatic process control PLC Level monitoring disinfectant, Calzid-Ex Switch inductive In-process cleaning with Calzid-Ex (organic acid mixture) automated Consumption of Calzid-Ex depending on drinking water hardness Operating temperature in the room °C 15 - 35 Relative humidity % < 45 Protection class IP 54 Connections Power inlet (frequency 50 Hz) V AC 230 ± 10% Power consumption W 350 Fuse A 13 Drinking water connection DN 15, AG ½“ Drinking water volume l/h 50 Unit feed water hardness °dH < 2 Drinking water temperature °C 15 - 22 Minimum drinking water pressure at the unit inlet bar 3,0 Minimum drain connection DN 65 Drain connection (pipe diffusion sealed) DN min. 20 Ventilation m3/h 20 Saline solution tank l 100 Natriumhypochlorit tank l 60 Calzid-Ex tank l 60 Dimensions (W x H x D) 1472 x 1750 x 574 Wall mounting (W x H) 1800 x 2000 Unit weight (tank empty) kg 90 Unit weight (tank full) kg 235 Certification CE approved Approval of the disinfectant German Drinking Water Ordinance Sect. 11 Maintenance interval annual Additives High-purity salt kg 25 Calzid-Ex kg 25 7
Page8

GF Piping Systems Worldwide at home Our sales companies and representatives ensure local customer support in over 100 countries. www.gfps.com Argentina / Southern South America France Middle East Spain / Portugal Georg Fischer Central Plastics Georg Fischer SAS Georg Fischer Georg Fischer S.A. Sudamérica S.R.L. 95932 Roissy Charles de Gaulle Cedex Piping Systems (Switzerland) Ltd 28046 Madrid Buenos Aires, Argentina Phone +33 (0)1 41 84 68 84 Dubai, United Arab Emirates Phone +34 (0) 91 781 98 90 Phone +5411 4512 02 90 Fax. +33 (0)1 41 84 68 85 Phone +971 4 289 49 60 Fax +34 (0) 91 426 08 23 Fax +5411 4512 02 93 fr.ps@georgfischer.com Fax +971 4 289 49 57 es.ps@georgfischer.com gfcentral.ps.ar@georgfischer.com www.gfps.com/fr gss.ps@georgfischer.com www.gfps.com/es www.gfps.com/ar www.gfps.com/int Germany Sweden Australia Georg Fischer GmbH Netherlands Georg Fischer AB George Fischer Pty Ltd 73095 Albershausen Georg Fischer N.V. 11743 Stockholm Riverwood NSW 2210 Phone +49 (0)7161 302 0 8161 PA Epe Phone +46 (0) 8 506 77 50 0 Phone +61 (0)2 9502 8000 Fax +49 (0)7161 302 25 9 Phone +31 (0) 578 678 222 Fax +46 (0) 8 749 23 70 Fax +61 (0)2 9502 8090 info.de.ps@georgfischer.com Fax +31 (0) 578 621 768 info.se.ps@georgfischer.com australia.ps@georgfischer.com www.gfps.com/de nl.ps@georgfischer.com www.gfps.com/se www.gfps.com/au www.gfps.com/nl India Switzerland Austria Georg Fischer Piping Systems Pvt. Ltd. New Zealand Georg Fischer Georg Fischer Rohrleitungssysteme GmbH 400 076 Powai, Mumbai Georg Fischer Ltd Rohrleitungssysteme (Switzerland) AG 3130 Herzogenburg Phone +91 22 4007 2001 5140 Upper Hutt 8201 Schaffhausen Phone +43 (0) 2782 856 43 0 Fax +91 22 4007 2020 Phone +64 (0) 4 527 9813 Phone +41 (0)52 631 30 26 Fax +43 (0) 2782 856 64 branchoffice@georgfischer.com Fax +64 (0) 4 527 9834 Fax +41 (0)52 631 28 00 austria.ps@georgfischer.com www.gfps.com/in nz.ps@georgfischer.com ch.ps@georgfischer.com www.gfps.com/at www.gfps.com/nz www.gfps.com/ch Indonesia Belgium / Luxembourg George Fischer Representative Office Norway Taiwan Georg Fischer NV/SA 10310 Jakarta Georg Fischer AS Georg Fischer Co. Ltd. 1070 Bruxelles/Brüssel, Belgium Phone +62 21 391 48 62 1351 Rud 24158 New Taipei City Phone +32 (0)2 556 40 20 Fax +62 21 391 48 63 Phone +47 67 18 29 00 Phone +886 2 8512 2822 Fax +32 (0)2 524 34 26 sgp.ps@georgfischer.com Fax +47 67 13 92 92 Fax +886 2 8512 2823 be.ps@georgfischer.com www.gfps.com/sg no.ps@georgfischer.com tw@georgfischer.com www.gfps.com/be www.gfps.com/no www.gfps.com/tw Italy Brazil Georg Fischer S.p.A. Philippines Turkey Georg Fischer Sist. de Tub. Ltda. 20063 Cernusco S/N (MI) George Fischer Representative Office Georg Fischer Hakan Plastik 04571-020 São Paulo/SP Phone +39 02 921 86 1 1604 Pasig City Boru ve Profil San. Tic. A.S. Phone +55 (0)11 5525 1311 Fax +39 02 921 86 24 7 Phone +632 571 2365 59500 Cerkezkoy / Tekirdag br.ps@georgfischer.com it.ps@georgfischer.com Fax +632 571 2368 Phone +90 282 726 64 43 www.gfps.com/br www.gfps.com/it sgp.ps@georgfischer.com Fax +90 282 726 94 67 www.gfps.com/sg hpsales@hakan.com.tr Canada Japan www.hakan.com.tr Georg Fischer Piping Systems Ltd Georg Fischer Ltd Poland Mississauga, ON L5T 2B2 556-0011 Osaka Georg Fischer Sp. z o.o. United Kingdom / Ireland Phone +1 (905) 670 8005 Phone +81 (0)6 6635 2691 05 090 Sekocin Nowy George Fischer Sales Ltd Fax +1 (905) 670 8513 Fax +81 (0)6 6635 2696 Phone +48 (0)22 3131 050 CV2 2ST Coventry, United Kingdom ca.ps@georgfischer.com jp.ps@georgfischer.com Fax +48 (0)22 3131 060 Phone +44 (0) 2476 535 535 www.gfps.com/ca www.gfps.com/jp poland.ps@georgfischer.com Fax +44 (0) 2476 530 450 www.gfps.com/pl uk.ps@georgfischer.com China Korea www.gfps.com/uk Georg Fischer P iping Systems Ltd Georg Fischer Piping Systems Romania 201319 Shanghai 463-824 Seoul Georg Fischer Rohrleitungssysteme (Elvetia) USA /Caribbean Phone +86 21 3899 3899 Phone +82 31 8017 1450 3 S.A. SUCURSALA BUCURESTI Georg Fischer LLC Fax +86 21 3899 3888 Fax +82 31 8017 1454 020257 Bucuresti 92618 Irvine china.ps@georgfischer.com kor.ps@georgfischer.com Phone +40 311 040 492 Phone +1 714 731 88 00 www.gfps.com/cn www.gfps.com/kr Fax +40 212 317 479 Fax +1 714 731 62 01 ro.ps@georgfischer.com Toll Free 800/854 40 90 Denmark / Iceland Malaysia www.gfps.com/int us.ps@georgfischer.com Georg Fischer A/S George Fischer (M) Sdn. Bhd. Sales Office www.gfpiping.com 2630 Taastrup, Denmark 40460 Shah Alam, Selangor Darul Ehsan Russia Phone +45 (0) 7022 1975 Phone +60 (0)3 5122 5585 Georg Fischer International Fax +45 (0) 7022 1976 Fax +60 (0)3 5122 5575 Piping Systems (Switzerland) Ltd Georg Fischer info.dk.ps@georgfischer.com my.ps@georgfischer.com Moscow Representative Office Piping Systems (Switzerland) Ltd www.gfps.com/dk www.gfps.com/my 125047 Moscow 8201 Schaffhausen/Switzerland Phone +7 495 258 60 80 Phone +41 (0) 52 631 30 03 Finland Mexico / Northern Latin America Fax +7 495 258 60 81 Fax +41 (0) 52 631 28 93 Georg Fischer AB Georg Fischer S.A. de C.V. ru.ps@georgfischer.com info.export@georgfischer.com 01510 Vantaa Apodaca, Nuevo Leon, Mexico www.gfps.com/ru www.gfps.com/int Phone +358 (0)9 586 58 25 Phone +52 (81) 1340 8586 Fax +358 (0)9 586 58 29 Fax +52 (81) 1522 8906 Singapore info.fi.ps@georgfischer.com mx.ps@georgfischer.com George Fischer Pte Ltd www.gfps.com/fi www.gfps.com/mx 528 872 Singapore Phone +65 6747 0611 Fax +65 6747 05 77 sgp.ps@georgfischer.com www.gfps.com/sg The technical data are not binding. They neither constitute expressly 3377 723429 62 warranted characteristics nor guaranteed properties nor a guaranteed durability. e2 ((41.1.61)4 S) MSMS S They are subject to modification. Our General Terms of Sale apply. © G Geeoorrgg F Fisiscchheer rJ RJRGG A GA G Haauuppttsstrtraasssee 1 13300 CCHH--44445500 S Sisissaacchh/S/Swwitiztezrelralnadn d TTeelleeffoonn + +4411 ( 0(0) )6 611 9 97755 2 222 2 222 iinnffoo..jrjrgg.p.pss@@ggeeoorrggfifsiscchheer.rc.ocmom Prrinintteedd i nin S Swwitiztzeerlralanndd