1/8ページ
Download(2.8Mb)
Connect CC-Link devices to CC-Link IE TSN networks
Connect CC-Link devices to CC-Link IE TSN networks
Document Information
| Document Title | CC-Link IE TSN - CC-Link Bridge Module |
|---|---|
| Document Type | Product Catalog |
| File size | 2.8Mb |
| Company | 三菱電機エンジニアリング株式会社 (Documents List) |
Document Contents
Page1
Product configuration
Model Included items:
• Manual (Hardware)
FA3-BR1TC • Screw-in installation bracket CC-Link IE TSN - CC-Link Bridge Module
• RJ45 dust cap
FA3-BR1TC
External dimensions
No. 24-03E
Connect CC-Link devices to
CC-Link IE TSN networks
40
54 70
67 86
Related information
CC-Link Partner Association website
https://www.cc-link.org/
The company names and product names mentioned in this document are either registered trademarks or trademarks of their respective companies.
In some cases, trademark symbols such as '™' or '®' are not specified in this document.
NAGOYA ENGINEERING OFFICE 1-9, Daiko-Minami, 1-Chome, Higashi-ku, Nagoya, Aichi 461-0047 Japan
Website www.mitsubishielectricengineering.com/sales/fa/meefan/ ▶Contact US
IT system
Network device Edge computing
Precautions for Choosing the Products For safe use
Mitsubishi Electric Engineering will not be held liable for damage caused ●To use the products given in this publication properly, always read the relevant manuals before beginning
operation. Product ion s i te
by factors found not to be the cause of Mitsubishi Electric Engineering;
opportunity losses or lost profits caused by faults in the Mitsubishi Electric ●The products have been manufactured as general-purpose parts for general industries, and are not designed or
Engineering products; damage, secondary damage, accident manufactured to be incorporated in a device or system used in purposes related to human life. Upgrade
●Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine or Source: Mitsubishi Electric Corporation
compensation caused by special factors unpredictable by Mitsubishi passenger-carrying vehicles, consult with Mitsubishi Electric Engineering.
Electric Engineering; damages to products other than Mitsubishi Electric ●The products have been manufactured under strict quality control. However, when installing the products where major
Engineering products; and to other duties. accidents or losses could occur if the products fail, install appropriate backup or fail-safe functions in the system.
Published in October 2024
MEIC242E・249 Specifications are subject to change without notice.
105
6 9.5 73.5
21.5 35.6
Page2
Product overview Setup support
Connect CC-Link devices to CC-Link IE TSN networks Simple configuration using our engineering tool
There is no need to setup multiple engineering tools and
configure individual settings. CC-Link IE TSN and CC-Link devices
R61P can be configured with one tool.
F L F L
Robot Solenoid valve Flow meter
L ER L ER
N
N C
USB C 1 LINK LINK
D 2
S A 3
L L ER L ER
4
D D
B 5
SPEED 6
D 7 LINK LINK
G STEP 1 Startup tool
MELSEC SD/RD
Startup GX Works3
(a Mitsubishi Electric product).
HMI Network STEP 2 Add modules
Remote I/O
(GOT) Servo Bridge module
interface FA3-BR1TC
module Select modules from the "Module List"
in the "CC-Link IE TSN Configuration" window.
Control CC-Link devices from CC-Link IE TSN devices
• CC-Link master not required
• Control devices not in the CC-Link IE TSN lineup
Upgrade to CC-Link IE TSN in stages
Select modules*
* If the module is not displayed in the list, import the CSP+ file.
Remote I/O Flow meter Solenoid valve Indicator
STEP 3 Parameter settings
Upgrade to
R61P
F L F L CC-Link IE TSN in stages • CC-Link IE TSN and CC-Link parameters can be configured without any
L ER L ER
N
N C programming.
USB C 1 LINK LINK
D 2
S A 3
L L ER L ER
D 4
D
B 5
SPEED 6
D 7 LINK LINK
G
MELSEC SD/RD • There is no need to setup multiple engineering tools.
• The automatic detection function of the CC-Link system is supported.
HMI Bridge module
Remote I/O
(GOT) Servo FA3-BR1TC Solenoid valve Indicator
Use existing devices, wiring, and operation data
• Using existing devices and wiring helps to cut costs and reduce construction time.
• Reusing devices reduces plastic usage. Settings can be configured
• Collect new line/facility data and inspect it with MELSOFT GEMINI (a Mitsubishi Electric product). without programming
• Reuse old line or facility operation data for new lines/facilities.
2
Page3
Product overview Setup support
Connect CC-Link devices to CC-Link IE TSN networks Simple configuration using our engineering tool
There is no need to setup multiple engineering tools and
configure individual settings. CC-Link IE TSN and CC-Link devices
R61P can be configured with one tool.
F L F L
Robot Solenoid valve Flow meter
L ER L ER
N
N C
USB C 1 LINK LINK
D 2
S A 3
L L ER L ER
4
D D
B 5
SPEED 6
D 7 LINK LINK
G STEP 1 Startup tool
MELSEC SD/RD
Startup GX Works3
(a Mitsubishi Electric product).
HMI Network STEP 2 Add modules
Remote I/O
(GOT) Servo Bridge module
interface FA3-BR1TC
module Select modules from the "Module List"
in the "CC-Link IE TSN Configuration" window.
Control CC-Link devices from CC-Link IE TSN devices
• CC-Link master not required
• Control devices not in the CC-Link IE TSN lineup
Upgrade to CC-Link IE TSN in stages
Select modules*
* If the module is not displayed in the list, import the CSP+ file.
Remote I/O Flow meter Solenoid valve Indicator
STEP 3 Parameter settings
Upgrade to
R61P
F L F L CC-Link IE TSN in stages • CC-Link IE TSN and CC-Link parameters can be configured without any
L ER L ER
N
N C programming.
USB C 1 LINK LINK
D 2
S A 3
L L ER L ER
D 4
D
B 5
SPEED 6
D 7 LINK LINK
G
MELSEC SD/RD • There is no need to setup multiple engineering tools.
• The automatic detection function of the CC-Link system is supported.
HMI Bridge module
Remote I/O
(GOT) Servo FA3-BR1TC Solenoid valve Indicator
Use existing devices, wiring, and operation data
• Using existing devices and wiring helps to cut costs and reduce construction time.
• Reusing devices reduces plastic usage. Settings can be configured
• Collect new line/facility data and inspect it with MELSOFT GEMINI (a Mitsubishi Electric product). without programming
• Reuse old line or facility operation data for new lines/facilities.
3
Page4
Data communication between CC-Link IE TSN and CC-Link
Network status check with the engineering tool Both CC-Link word data and bit data can be read/written to and from
the CC-Link IE master station.
The status of the network during setup can be checked with one tool.
STEP 1 Startup tool STEP 2 Display the Configuration window
R61P
F L F L
L ER L ER
N
N C
USB C 1 LINK LINK
D 2
Startup GX Works3 S A 3
L L ER L ER
4
D D
B 5
SPEED 6
D 7 LINK LINK
G
MELSEC SD/RD
(a Mitsubishi Electric
product). CC-Link IE TSN master Station No. 5: Station No. 8:
Bridge module Indicator Flow meter
FA3-BR1TC
X RX RX
X RX RX
STEP 3 Check the connection status Y RY RY
Y RY RY
Display the "CC-Link IE TSN Configuration" window and check the network
connection status in the "Command Execution of Device Station" window.
Cyclic Cyclic
transmission transmission
W RWr RWr
W RWr RWr
W RWw RWw
W RWw RWw
Data link error example
Data link error
R61P
F L F L
L ER L ER
N
USB N C
C 1 LINK LINK
D 2
S A 3
L L ER L
D D 4 ER
B 5
SPEED 6
D
G 7 LINK LINK
MELSEC SD/RD
CC-Link IE TSN master Station No. 5: Station No. 8:
Indicator Flow meter
Bridge module
FA3-BR1TC
4
Page5
Data communication between CC-Link IE TSN and CC-Link
Network status check with the engineering tool Both CC-Link word data and bit data can be read/written to and from
the CC-Link IE master station.
The status of the network during setup can be checked with one tool.
STEP 1 Startup tool STEP 2 Display the Configuration window
R61P
F L F L
L ER L ER
N
N C
USB C 1 LINK LINK
D 2
Startup GX Works3 S A 3
L L ER L ER
4
D D
B 5
SPEED 6
D 7 LINK LINK
G
MELSEC SD/RD
(a Mitsubishi Electric
product). CC-Link IE TSN master Station No. 5: Station No. 8:
Bridge module Indicator Flow meter
FA3-BR1TC
X RX RX
X RX RX
STEP 3 Check the connection status Y RY RY
Y RY RY
Display the "CC-Link IE TSN Configuration" window and check the network
connection status in the "Command Execution of Device Station" window.
Cyclic Cyclic
transmission transmission
W RWr RWr
W RWr RWr
W RWw RWw
W RWw RWw
Data link error example
Data link error
R61P
F L F L
L ER L ER
N
USB N C
C 1 LINK LINK
D 2
S A 3
L L ER L
D D 4 ER
B 5
SPEED 6
D
G 7 LINK LINK
MELSEC SD/RD
CC-Link IE TSN master Station No. 5: Station No. 8:
Indicator Flow meter
Bridge module
FA3-BR1TC
5
Page6
Product specifications
Item Description
CC-Link IE TSN communication section RJ45 connector × 2
External connection method CC-Link communication section Terminal block for CC-Link system (2-piece spring clamp terminal)
Module power supply section Terminal block for module power supply and FG (2-piece spring clamp terminal block)
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (JIS C 2812 compliant)
Ethernet cable that meets the 1000BASE-T standard (straight/crossover)
1Gbps
Category 5e or higher (double-shielded, STP) cable
CC-Link IE TSN
Ethernet cable that meets the 100BASE-TX standard (straight/crossover)
100Mbps
Category 5 or higher (double-shielded, STP) cable
Ver.1.10-compatible CC-Link dedicated cable (Mitsubishi Electric FA-CBL200PSBH,
Connection cables and power
wires CC-Link FANC-110SBH, CS-110)
The terminal block slot size is 2.4mm × 1.5mm.
Wire size 0.14 to 1.5mm2 (24 to 16 AWG)
Module power Type Stranded wire or solid wire
supply/FG terminal Material Copper
Temperature rating 75°C or more
Voltage 24VDC (ripple rate within 5%) (permissible voltage: 20.4 to 28.8VDC)
Module power supply
Current 150mA
H (height) 105mm
W (width) 40mm
External Dimensions
70mm (excluding terminal block)
D (depth)
86mm (including terminal block)
Weight 180g
Network specifications
Item Description
Communication speed 1Gbps/100Mbps
Communication mode 1000BASE-T (full-duplex) / 100BASE-TX (full-duplex)
Station type Remote station
CC-Link IE TSN Certification class Class B Ver.2.0
Topology Line topology/Star topology/Mixture of star and line topology/Ring topology
RX/RY 3840 points (480 bytes)/3840 points (480 bytes)
Number of link points
RWw/RWr 960 points (1920 bytes)/960 points (1920 bytes)
Transmission speed Select from 156Kbps, 625Kbps, 2.5Mbps, 5Mbps, and 10Mbps.
CC-Link version Ver.2.00
Station type Master station
Maximum number of connectable stations 64 stations
CC-Link Remote I/O (RX/RY) 2048 points (256 bytes)/2048 points (256 bytes)
CC-Link M a x i m u m Ver.1 Remote register (RWw/RWr) 256 points (512 bytes)/256 points (512 bytes)
number of
link points CC-Link Remote I/O (RX/RY) 3584 points (448 bytes)/3584 points (448 bytes)
Ver.2 Remote register (RWw/RWr) 816 points (1632 bytes)/816 points (1632 bytes)
Station-to-station cable length (minimum station-to-station
distance) 20cm
Maximum overall cable length (maximum transmission 156Kbps: 1200m / 625Kbps: 900m / 2.5Mbps: 400m
distance) 5Mbps: 160m / 10Mbps: 100m
Versions that support CC-Link IE TSN
Class Support
Class A Ver.2.0 ×
Class B Ver.2.0 ✓
CC-Link connection specifications
Send station Receive station
CC-Link Ver.2.00 CC-Link Ver.2.00 CC-Link Ver.1.10
Master station Local Intelligent Remote Local Intelligent Remote Remote I/O
station device station device station station device station device station station
CC-Link IE TSN―CC-Link bridge module × × ✓*1 × × ✓*2 ✓*2
*1: Extended cyclic communication
*2: Cyclic communication
6
Page7
Function List
Common specifications
Function Description
Error history function Checks the error history of this module using the engineering tool.
Unit test function Checks for abnormalities with the module's hardware.
CC-Link IE TSN functions
Function Description
Error notification function Notifies the CC-Link IE TSN master station of CC-Link errors.
CC-Link IE TSN diagnostics Checks the status of the module using the engineering tool.
This function also checks the reasons of and solutions to errors.
Automatic parameter setting
function Automatically sets parameters via the master station when the module accesses or returns to the network.
CC-Link functions
Function Description
Communication using RX
Communication with and RY Communicates I/O data between the module and other stations with bits.
other stations Communication using RWr
and RWw Communicates I/O data between the module and other stations with words.
Link refresh Refreshes the CC-Link IE TSN and CC-Link data in the module.
Cyclic data assurance Prevents read/write data from being separated from new and old data.
Cyclic Input data from data link faulty station Holds or clears input data from stations with a faulty data link.
transmission CC-Link IE TSN Master station output Hold/Clear Holds or clears the refresh data of Remote output (RY) to 0 when CC-Link IE TSN
setting during CPU module STOP communications stop.
Data link setting at CPU module error on CC-Link IE
TSN master station Stops or resumes data link when the CC-Link IE TSN communications stop.
Setting at data link error on CC-Link IE TSN side Holds or clears data sent to CC-Link when a data link error occurs in the bridge module.
Data link stop and restart Stops or restarts data link during operations such as debugging.
Remote I/O station points setting 8, 16, or 32 refresh points can be selected.
Device station cut-off function Continues data link with normally operating stations and disconnects device stations that
cannot perform data link due to an error.
RAS
Automatic return function Automatically returns the disconnected device station to the network and restarts the data
link when a disconnected station returns to normal.
Line test Checks whether data link with the device station is possible.
Diagnostics
CC-Link diagnostics Checks the status of the CC-Link system.
Reserved station function Reserves a disconnected device station and does not recognize it as an error station.
Error invalid station setting function Prevents a device station from being detected as an error station.
Other
Temporary error invalid station setting function Temporarily prevents a station from being detected as an error station when a device
station data link error occurs.
Automatic detection of connected devices function Automatically detects connected devices in the "Device list".
7
Page8
Product configuration
Model Included items:
• Manual (Hardware)
FA3-BR1TC • Screw-in installation bracket CC-Link IE TSN - CC-Link Bridge Module
• RJ45 dust cap
FA3-BR1TC
External dimensions
No. 24-03E
Connect CC-Link devices to
CC-Link IE TSN networks
40
54 70
67 86
Related information
CC-Link Partner Association website
https://www.cc-link.org/
The company names and product names mentioned in this document are either registered trademarks or trademarks of their respective companies.
In some cases, trademark symbols such as '™' or '®' are not specified in this document.
NAGOYA ENGINEERING OFFICE 1-9, Daiko-Minami, 1-Chome, Higashi-ku, Nagoya, Aichi 461-0047 Japan
Website www.mitsubishielectricengineering.com/sales/fa/meefan/ ▶Contact US
IT system
Network device Edge computing
Precautions for Choosing the Products For safe use
Mitsubishi Electric Engineering will not be held liable for damage caused ●To use the products given in this publication properly, always read the relevant manuals before beginning
operation. Product ion s i te
by factors found not to be the cause of Mitsubishi Electric Engineering;
opportunity losses or lost profits caused by faults in the Mitsubishi Electric ●The products have been manufactured as general-purpose parts for general industries, and are not designed or
Engineering products; damage, secondary damage, accident manufactured to be incorporated in a device or system used in purposes related to human life. Upgrade
●Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine or Source: Mitsubishi Electric Corporation
compensation caused by special factors unpredictable by Mitsubishi passenger-carrying vehicles, consult with Mitsubishi Electric Engineering.
Electric Engineering; damages to products other than Mitsubishi Electric ●The products have been manufactured under strict quality control. However, when installing the products where major
Engineering products; and to other duties. accidents or losses could occur if the products fail, install appropriate backup or fail-safe functions in the system.
Published in October 2024
MEIC242E・249 Specifications are subject to change without notice.
105
6 9.5 73.5
21.5 35.6