Page1

Product configuration Model Included items: • Manual (Hardware) FA3-BR1TC • Screw-in installation bracket CC-Link IE TSN - CC-Link Bridge Module • RJ45 dust cap FA3-BR1TC External dimensions No. 24-03E Connect CC-Link devices to CC-Link IE TSN networks 40 54 70 67 86 Related information CC-Link Partner Association website https://www.cc-link.org/ The company names and product names mentioned in this document are either registered trademarks or trademarks of their respective companies. In some cases, trademark symbols such as '™' or '®' are not specified in this document. NAGOYA ENGINEERING OFFICE 1-9, Daiko-Minami, 1-Chome, Higashi-ku, Nagoya, Aichi 461-0047 Japan Website www.mitsubishielectricengineering.com/sales/fa/meefan/ ▶Contact US IT system Network device Edge computing Precautions for Choosing the Products For safe use Mitsubishi Electric Engineering will not be held liable for damage caused ●To use the products given in this publication properly, always read the relevant manuals before beginning operation. Product ion s i te by factors found not to be the cause of Mitsubishi Electric Engineering; opportunity losses or lost profits caused by faults in the Mitsubishi Electric ●The products have been manufactured as general-purpose parts for general industries, and are not designed or Engineering products; damage, secondary damage, accident manufactured to be incorporated in a device or system used in purposes related to human life. Upgrade ●Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine or Source: Mitsubishi Electric Corporation compensation caused by special factors unpredictable by Mitsubishi passenger-carrying vehicles, consult with Mitsubishi Electric Engineering. Electric Engineering; damages to products other than Mitsubishi Electric ●The products have been manufactured under strict quality control. However, when installing the products where major Engineering products; and to other duties. accidents or losses could occur if the products fail, install appropriate backup or fail-safe functions in the system. Published in October 2024 MEIC242E・249 Specifications are subject to change without notice. 105 6 9.5 73.5 21.5 35.6
Page2

Product overview Setup support Connect CC-Link devices to CC-Link IE TSN networks Simple configuration using our engineering tool There is no need to setup multiple engineering tools and configure individual settings. CC-Link IE TSN and CC-Link devices R61P can be configured with one tool. F L F L Robot Solenoid valve Flow meter L ER L ER N N C USB C 1 LINK LINK D 2 S A 3 L L ER L ER 4 D D B 5 SPEED 6 D 7 LINK LINK G STEP 1 Startup tool MELSEC SD/RD Startup GX Works3 (a Mitsubishi Electric product). HMI Network STEP 2 Add modules Remote I/O (GOT) Servo Bridge module interface FA3-BR1TC module Select modules from the "Module List" in the "CC-Link IE TSN Configuration" window. Control CC-Link devices from CC-Link IE TSN devices • CC-Link master not required • Control devices not in the CC-Link IE TSN lineup Upgrade to CC-Link IE TSN in stages Select modules* * If the module is not displayed in the list, import the CSP+ file. Remote I/O Flow meter Solenoid valve Indicator STEP 3 Parameter settings Upgrade to R61P F L F L CC-Link IE TSN in stages • CC-Link IE TSN and CC-Link parameters can be configured without any L ER L ER N N C programming. USB C 1 LINK LINK D 2 S A 3 L L ER L ER D 4 D B 5 SPEED 6 D 7 LINK LINK G MELSEC SD/RD • There is no need to setup multiple engineering tools. • The automatic detection function of the CC-Link system is supported. HMI Bridge module Remote I/O (GOT) Servo FA3-BR1TC Solenoid valve Indicator Use existing devices, wiring, and operation data • Using existing devices and wiring helps to cut costs and reduce construction time. • Reusing devices reduces plastic usage. Settings can be configured • Collect new line/facility data and inspect it with MELSOFT GEMINI (a Mitsubishi Electric product). without programming • Reuse old line or facility operation data for new lines/facilities. 2
Page3

Product overview Setup support Connect CC-Link devices to CC-Link IE TSN networks Simple configuration using our engineering tool There is no need to setup multiple engineering tools and configure individual settings. CC-Link IE TSN and CC-Link devices R61P can be configured with one tool. F L F L Robot Solenoid valve Flow meter L ER L ER N N C USB C 1 LINK LINK D 2 S A 3 L L ER L ER 4 D D B 5 SPEED 6 D 7 LINK LINK G STEP 1 Startup tool MELSEC SD/RD Startup GX Works3 (a Mitsubishi Electric product). HMI Network STEP 2 Add modules Remote I/O (GOT) Servo Bridge module interface FA3-BR1TC module Select modules from the "Module List" in the "CC-Link IE TSN Configuration" window. Control CC-Link devices from CC-Link IE TSN devices • CC-Link master not required • Control devices not in the CC-Link IE TSN lineup Upgrade to CC-Link IE TSN in stages Select modules* * If the module is not displayed in the list, import the CSP+ file. Remote I/O Flow meter Solenoid valve Indicator STEP 3 Parameter settings Upgrade to R61P F L F L CC-Link IE TSN in stages • CC-Link IE TSN and CC-Link parameters can be configured without any L ER L ER N N C programming. USB C 1 LINK LINK D 2 S A 3 L L ER L ER D 4 D B 5 SPEED 6 D 7 LINK LINK G MELSEC SD/RD • There is no need to setup multiple engineering tools. • The automatic detection function of the CC-Link system is supported. HMI Bridge module Remote I/O (GOT) Servo FA3-BR1TC Solenoid valve Indicator Use existing devices, wiring, and operation data • Using existing devices and wiring helps to cut costs and reduce construction time. • Reusing devices reduces plastic usage. Settings can be configured • Collect new line/facility data and inspect it with MELSOFT GEMINI (a Mitsubishi Electric product). without programming • Reuse old line or facility operation data for new lines/facilities. 3
Page4

Data communication between CC-Link IE TSN and CC-Link Network status check with the engineering tool Both CC-Link word data and bit data can be read/written to and from the CC-Link IE master station. The status of the network during setup can be checked with one tool. STEP 1 Startup tool STEP 2 Display the Configuration window R61P F L F L L ER L ER N N C USB C 1 LINK LINK D 2 Startup GX Works3 S A 3 L L ER L ER 4 D D B 5 SPEED 6 D 7 LINK LINK G MELSEC SD/RD (a Mitsubishi Electric product). CC-Link IE TSN master Station No. 5: Station No. 8: Bridge module Indicator Flow meter FA3-BR1TC X RX RX X RX RX STEP 3 Check the connection status Y RY RY Y RY RY Display the "CC-Link IE TSN Configuration" window and check the network connection status in the "Command Execution of Device Station" window. Cyclic Cyclic transmission transmission W RWr RWr W RWr RWr W RWw RWw W RWw RWw Data link error example Data link error R61P F L F L L ER L ER N USB N C C 1 LINK LINK D 2 S A 3 L L ER L D D 4 ER B 5 SPEED 6 D G 7 LINK LINK MELSEC SD/RD CC-Link IE TSN master Station No. 5: Station No. 8: Indicator Flow meter Bridge module FA3-BR1TC 4
Page5

Data communication between CC-Link IE TSN and CC-Link Network status check with the engineering tool Both CC-Link word data and bit data can be read/written to and from the CC-Link IE master station. The status of the network during setup can be checked with one tool. STEP 1 Startup tool STEP 2 Display the Configuration window R61P F L F L L ER L ER N N C USB C 1 LINK LINK D 2 Startup GX Works3 S A 3 L L ER L ER 4 D D B 5 SPEED 6 D 7 LINK LINK G MELSEC SD/RD (a Mitsubishi Electric product). CC-Link IE TSN master Station No. 5: Station No. 8: Bridge module Indicator Flow meter FA3-BR1TC X RX RX X RX RX STEP 3 Check the connection status Y RY RY Y RY RY Display the "CC-Link IE TSN Configuration" window and check the network connection status in the "Command Execution of Device Station" window. Cyclic Cyclic transmission transmission W RWr RWr W RWr RWr W RWw RWw W RWw RWw Data link error example Data link error R61P F L F L L ER L ER N USB N C C 1 LINK LINK D 2 S A 3 L L ER L D D 4 ER B 5 SPEED 6 D G 7 LINK LINK MELSEC SD/RD CC-Link IE TSN master Station No. 5: Station No. 8: Indicator Flow meter Bridge module FA3-BR1TC 5
Page6

Product specifications Item Description CC-Link IE TSN communication section RJ45 connector × 2 External connection method CC-Link communication section Terminal block for CC-Link system (2-piece spring clamp terminal) Module power supply section Terminal block for module power supply and FG (2-piece spring clamp terminal block) Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (JIS C 2812 compliant) Ethernet cable that meets the 1000BASE-T standard (straight/crossover) 1Gbps Category 5e or higher (double-shielded, STP) cable CC-Link IE TSN Ethernet cable that meets the 100BASE-TX standard (straight/crossover) 100Mbps Category 5 or higher (double-shielded, STP) cable Ver.1.10-compatible CC-Link dedicated cable (Mitsubishi Electric FA-CBL200PSBH, Connection cables and power wires CC-Link FANC-110SBH, CS-110) The terminal block slot size is 2.4mm × 1.5mm. Wire size 0.14 to 1.5mm2 (24 to 16 AWG) Module power Type Stranded wire or solid wire supply/FG terminal Material Copper Temperature rating 75°C or more Voltage 24VDC (ripple rate within 5%) (permissible voltage: 20.4 to 28.8VDC) Module power supply Current 150mA H (height) 105mm W (width) 40mm External Dimensions 70mm (excluding terminal block) D (depth) 86mm (including terminal block) Weight 180g Network specifications Item Description Communication speed 1Gbps/100Mbps Communication mode 1000BASE-T (full-duplex) / 100BASE-TX (full-duplex) Station type Remote station CC-Link IE TSN Certification class Class B Ver.2.0 Topology Line topology/Star topology/Mixture of star and line topology/Ring topology RX/RY 3840 points (480 bytes)/3840 points (480 bytes) Number of link points RWw/RWr 960 points (1920 bytes)/960 points (1920 bytes) Transmission speed Select from 156Kbps, 625Kbps, 2.5Mbps, 5Mbps, and 10Mbps. CC-Link version Ver.2.00 Station type Master station Maximum number of connectable stations 64 stations CC-Link Remote I/O (RX/RY) 2048 points (256 bytes)/2048 points (256 bytes) CC-Link M a x i m u m Ver.1 Remote register (RWw/RWr) 256 points (512 bytes)/256 points (512 bytes) number of link points CC-Link Remote I/O (RX/RY) 3584 points (448 bytes)/3584 points (448 bytes) Ver.2 Remote register (RWw/RWr) 816 points (1632 bytes)/816 points (1632 bytes) Station-to-station cable length (minimum station-to-station distance) 20cm Maximum overall cable length (maximum transmission 156Kbps: 1200m / 625Kbps: 900m / 2.5Mbps: 400m distance) 5Mbps: 160m / 10Mbps: 100m Versions that support CC-Link IE TSN Class Support Class A Ver.2.0 × Class B Ver.2.0 ✓ CC-Link connection specifications Send station Receive station CC-Link Ver.2.00 CC-Link Ver.2.00 CC-Link Ver.1.10 Master station Local Intelligent Remote Local Intelligent Remote Remote I/O station device station device station station device station device station station CC-Link IE TSN―CC-Link bridge module × × ✓*1 × × ✓*2 ✓*2 *1: Extended cyclic communication *2: Cyclic communication 6
Page7

Function List Common specifications Function Description Error history function Checks the error history of this module using the engineering tool. Unit test function Checks for abnormalities with the module's hardware. CC-Link IE TSN functions Function Description Error notification function Notifies the CC-Link IE TSN master station of CC-Link errors. CC-Link IE TSN diagnostics Checks the status of the module using the engineering tool. This function also checks the reasons of and solutions to errors. Automatic parameter setting function Automatically sets parameters via the master station when the module accesses or returns to the network. CC-Link functions Function Description Communication using RX Communication with and RY Communicates I/O data between the module and other stations with bits. other stations Communication using RWr and RWw Communicates I/O data between the module and other stations with words. Link refresh Refreshes the CC-Link IE TSN and CC-Link data in the module. Cyclic data assurance Prevents read/write data from being separated from new and old data. Cyclic Input data from data link faulty station Holds or clears input data from stations with a faulty data link. transmission CC-Link IE TSN Master station output Hold/Clear Holds or clears the refresh data of Remote output (RY) to 0 when CC-Link IE TSN setting during CPU module STOP communications stop. Data link setting at CPU module error on CC-Link IE TSN master station Stops or resumes data link when the CC-Link IE TSN communications stop. Setting at data link error on CC-Link IE TSN side Holds or clears data sent to CC-Link when a data link error occurs in the bridge module. Data link stop and restart Stops or restarts data link during operations such as debugging. Remote I/O station points setting 8, 16, or 32 refresh points can be selected. Device station cut-off function Continues data link with normally operating stations and disconnects device stations that cannot perform data link due to an error. RAS Automatic return function Automatically returns the disconnected device station to the network and restarts the data link when a disconnected station returns to normal. Line test Checks whether data link with the device station is possible. Diagnostics CC-Link diagnostics Checks the status of the CC-Link system. Reserved station function Reserves a disconnected device station and does not recognize it as an error station. Error invalid station setting function Prevents a device station from being detected as an error station. Other Temporary error invalid station setting function Temporarily prevents a station from being detected as an error station when a device station data link error occurs. Automatic detection of connected devices function Automatically detects connected devices in the "Device list". 7
Page8

Product configuration Model Included items: • Manual (Hardware) FA3-BR1TC • Screw-in installation bracket CC-Link IE TSN - CC-Link Bridge Module • RJ45 dust cap FA3-BR1TC External dimensions No. 24-03E Connect CC-Link devices to CC-Link IE TSN networks 40 54 70 67 86 Related information CC-Link Partner Association website https://www.cc-link.org/ The company names and product names mentioned in this document are either registered trademarks or trademarks of their respective companies. In some cases, trademark symbols such as '™' or '®' are not specified in this document. NAGOYA ENGINEERING OFFICE 1-9, Daiko-Minami, 1-Chome, Higashi-ku, Nagoya, Aichi 461-0047 Japan Website www.mitsubishielectricengineering.com/sales/fa/meefan/ ▶Contact US IT system Network device Edge computing Precautions for Choosing the Products For safe use Mitsubishi Electric Engineering will not be held liable for damage caused ●To use the products given in this publication properly, always read the relevant manuals before beginning operation. Product ion s i te by factors found not to be the cause of Mitsubishi Electric Engineering; opportunity losses or lost profits caused by faults in the Mitsubishi Electric ●The products have been manufactured as general-purpose parts for general industries, and are not designed or Engineering products; damage, secondary damage, accident manufactured to be incorporated in a device or system used in purposes related to human life. Upgrade ●Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine or Source: Mitsubishi Electric Corporation compensation caused by special factors unpredictable by Mitsubishi passenger-carrying vehicles, consult with Mitsubishi Electric Engineering. Electric Engineering; damages to products other than Mitsubishi Electric ●The products have been manufactured under strict quality control. However, when installing the products where major Engineering products; and to other duties. accidents or losses could occur if the products fail, install appropriate backup or fail-safe functions in the system. Published in October 2024 MEIC242E・249 Specifications are subject to change without notice. 105 6 9.5 73.5 21.5 35.6