1/12ページ
Download(2.8Mb)
Smart Production Sites with IoT
Do you have any concerns or requests?
case01 Monitoring on-site operating conditions
Small IoT system for integrated management of device data
case02 Meeting user-selected network specifications
Switching cnnection to various types of network
case03 Facilitating wiring from the control panel to the system
Easy wiring from the contro-l panel to the system
case04 Reducing intial cost and maintenance cost
Optimum system configuration using modules
case05 Constructing a system the incorporates a function to prevent troubles and identify the cause
Operation data recording function for preventing and solving troubles
Document Information
| Document Title | Network Interface Modules |
|---|---|
| Document Type | Product Catalog |
| File size | 2.8Mb |
| Category | |
| Company | 三菱電機エンジニアリング株式会社 (Documents List) |
Document Contents
Page2
2
Page3
3
Page4
4
Page5
5
Page6
■Products and combinations
When a digital signal converter (terminal module) is used Ensure compliance with required international standards also for other products used in combination.
Programmable Network interface module Digital signal converter (terminal module)
controller
IPC Terminal block
Name Model Control method Model
type
Installation base unit 4 points, independent FA1-TH4X2SC20S1E
Spring clamp type
(module selectable type) 8 points, independent FA1-TH8X2SC20S1E
4 points, independent (positive) FA1-TH4X24RA1L20S1E
Spring clamp type
4 points, independent (negative) FA1-TH4X24RA1H20S1E
Module 8 points, independent (positive) FA1-TH8X24RA1L20S1E
Spring clamp type
pre-mounted 8 points, independent (negative) FA1-TH8X24RA1H20S1E
unit 24VDC 16 points, independent (positive) FA1-TH16X24RA1L20S1E
Dedicated cable included Spring clamp type
(N/O 16 points, independent (negative) FA1-TH16X24RA1H20S1E
Digital signal converter FA3-TH1□16XC-01C contact) 16 points, independent Screw type (M3) FA-TH16XRA20S
CC-Link IE TSN Input model Dedicated cable not included
master station FA3-TH1□16XC Screw type (M3) FA-TH16X24D31
24VDC 16 points/common, 2-wire type
● MELSEC iQ-R Screw type (M3.5) FA-TH16X24D31L
● MELSEC iQ-F 48VDC 16 points/common, 2-wire type Screw type (M3.5) FA-TH16X48D31L
Module built-in 100VDC 16 points/common, 2-wire type Screw type (M3.5) FA-TH16X100D31L
CC-Link IE Field unit Screw type (M3) FA-TH16X100A31
master station 100VAC 16 points/common, 2-wire type
● MELIPC Screw type (M3.5) FA-TH16X100A31L
● MELSEC iQ-R Screw type (M3) FA-TH16X200A31
200VAC 16 points/common, 2-wire type
● MELSEC iQ-F Screw type (M3.5) FA-TH16X200A31L
● MELSEC-Q
● MELSEC-L 4 points, independent (sink) FA1-TH4Y2SC20S1E
● MELSEC-F Installation base unit
8 points, independent (sink) Spring clamp type FA1-TH8Y2SC20S1E
(module selectable type)
CC-Link IE Field 16 points, independent (sink) FA1-TH16Y2SC20S1E
Basic master Spring clamp type FA1-TH16Y2RA20S1E
station FA-TH16YRA20S
● 16 points, independent Screw type (M3)
MELIPC FA-TH16YRA20
● MELSEC iQ-R
N/O contact Screw type (M3.5) FA-TH16YRA20SL
● MELSEC iQ-F
relay FA-TH16YRA11S
● MELSEC-Q 16 points/common, 1-wire type Screw type (M3)
● MELSEC-L FA-TH16YRA11
FA-TH16YRA21S
16 points/common, 2-wire type Screw type (M3)
SLMP FA-TH16YRA21
client N/C contact
● MELIPC 16 points, independent Screw type (M3.5) FA-TH16YRAB20SL
relay
● MELSEC iQ-R Dedicated cable included C/O contact
● MELSEC iQ-F Digital signal converter FA3-TH1□16Y-01C 16 points, independent Screw type (M3) FA-TH16YRAC20S
Module relay
● MELSEC-Q Output model (sink) Dedicated cable not included pre-mounted Spring clamp type FA1-TH16Y1SR20S1E
● MELSEC-L FA3-TH1□16Y unit 16 points, independent
● MELSEC-F Screw type (M3) FA-TH16YSR20S
Triac
16 points/common, 1-wire type Screw type (M3) FA-TH16YSR11S
MODBUS/TCP 16 points/common, 2-wire type Screw type (M3) FA-TH16YSR21S
● MELSEC iQ-R 16 points, independent (sink) Spring clamp type FA1-TH16Y1TR20S1E
● MELSEC-Q 16 points/common,
● MELSEC-L Screw type (M3) FA-TH16YTL11S
1-wire type (sink)
16 points/common,
CC-Link master Screw type (M3) FA-TH16YTL21S
2-wire type (sink)
station Transistor
● MELSEC iQ-R 16 points/common,
(sink) Screw type (M3) FA-TH16YTH11S
● MELSEC iQ-F 1-wire type (source)
● MELSEC-Q 16 points, independent
Screw type (M3) FA-TH16YTR20S
● MELSEC-L (sink/source common)
● MELSEC-F Module built-in 16 points, independent,
Screw type (M3) FA-TH16Y2TR20
unit 2A (sink/source common)
General-purpose
controller
4 points, independent (sink) FA1-TH1E4Y2SC20S1E
(general-purpose Installation base unit
8 points, independent (sink) Spring clamp type FA1-TH1E8Y2SC20S1E
Ethernet) (module selectable type)
16 points, independent (source) FA1-TH1E16Y2SC20S1E
N/O contact 16 points, independent (source) Spring clamp type FA1-TH1E16Y2RA20S1E
Dedicated cable included
relay 16 points, independent (source) Screw type (M3) FA1-TH1E16Y2RA20S
Digital signal converter FA3-TH1□16YE-01C
Output model (source) Dedicated cable not included Triac 16 points, independent (source) Spring clamp type FA1-TH1E16Y1SR20S1E
Module
FA3-TH1□16YE 16 points, independent (source) Spring clamp type FA1-TH1E16Y1TR20S1E
pre-mounted
unit 16 points, independent
Transistor Screw type (M3) FA-THE16YTR20S
(sink/source common)
(source)
16 points/common,
Screw type (M3) FA-THE16YTH11S
1-wire type (source)
Available networks
□ = M CC-Link IE TSN, CC-Link IE Field, CC-Link IE Field Basic, SLMP (general-purpose Ethernet), MODBUS/TCP
□ = T CC-Link IE TSN, CC-Link IE Field, CC-Link IE Field Basic, SLMP (general-purpose Ethernet)
□ = C CC-Link
6
Page7
Module
Specifications
Model
(Signal pass-through modules are not supported.)
N/O contact relay (beige) Input: 24VDC 2 pcs FA-NYP24WK*
Input/output model
N/C contact relay (sky blue) Output: 24VDC, 100 to 240VAC, 2A 4 pcs FA-NYBP24WK*
Slim module C/O contact relay (white) 24VDC, 100 to 240VAC, 6A 4 pcs FA-LYCA024VSK4
Output model Triac (black) 30 to 240VAC, 1A 2 pcs FA-SN24A01FS*
Transistor (red) 3 to 30VDC, 1A 4 pcs FA-SN24D01HZS*
24VDC relay isolation (navy blue) FA1-TM1X24RA-*
24VDC photocoupler isolation (black) FA1-TM1X24D-*
48VDC photocoupler isolation (sky blue) 1 pce FA1-TM1X48D-*
Functional 2 pcs
Input model 100VDC photocoupler isolation (purple)
module 4 pcs FA1-TM1X100D-*
100VAC photocoupler isolation (orange) FA1-TM1X100A-*
200VAC photocoupler isolation (red) FA1-TM1X200A-*
Dummy module (dust protector) (green) 4 pcs FA1-TM1ND4
* is replaced with a number that corresponds to the number of modules.
It is replaced with "2" when two modules are included and "4" when four modules are included.
Digital signal converter (terminal module)
This converter is used to convert digital signals sent between the network interface module and sensors or other devices.
There are two types of terminal blocks: spring clamp type and screw type.
⨋ Input Spring clamp terminal type Screw terminal type
Different input voltages (24VDC, 48VDC, 100VDC, 100VAC, 200VAC) can be specified for each terminal according to the device type.
⨋ Output Spring clamp terminal type Screw terminal type
Different control methods (relay, triac, transistor) can be specified for each terminal according to the device type.
7
Page8
When an analog signal converter is used Ensure compliance with required international standards also for other products used in combination.
Programmable Network interface module Analog signal converter
controller Installation base Connectable module (Pass-through modules are not supported.)
IPC Name Model
Model Specifications Model
CC-Link IE TSN 0 to 5V FA-ATSVM1XV05
master station Voltage input 1 to 5V FA-ATSVM1XV15
● MELSEC iQ-R
● MELSEC iQ-F -10 to 10V FA-ATSVM1XV1010
Current input 4 to 20mA FA-ATSVM1XA420
CC-Link IE Field
master station Distributor
4 to 20mA FA-ATSVM1XD
● MELIPC (2-wire transmitter)
● MELSEC iQ-R Pt100 -200 to +650°C FA-ATSVM1XRPT
● MELSEC iQ-F
● MELSEC-Q Pt100 0 to +100°C FA-ATSVM1XRPT0010
● RTD input
MELSEC-L Pt100 0 to +200°C FA-ATSVM1XRPT0020
● MELSEC-F 4-channel
Dedicated cable FA1-AT1B4X1TE JPt100 -200 to +600°C FA-ATSVM1XRJPT
CC-Link IE Field included (spring clamp terminal block)
Analog signal Type B thermocouple +600 to +1700°C FA-ATSVM1XTB
Basic master station FA3-AT1□8X-01C FA1-AT1B4X1TB
● MELIPC converter (screw terminal block)
Dedicated cable + Type R thermocouple 0 to +1600°C FA-ATSVM1XTR
● MELSEC iQ-R Input model
not included
● MELSEC iQ-F 8-channel Type S thermocouple 0 to +1600°C FA-ATSVM1XTS
FA3-AT1□8X
● MELSEC-Q FA-ATB8XTB -200 to +1200°C FA-ATSVM1XTK
● MELSEC-L (screw terminal block)
0 to +400°C FA-ATSVM1XTK0040
SLMPclient Type K thermocouple
Thermocouple input 0 to +600°C FA-ATSVM1XTK0060
● MELIPC
● MELSEC iQ-R 0 to +800°C FA-ATSVM1XTK0080
● MELSEC iQ-F
● Type E thermocouple -200 to +900°C FA-ATSVM1XTE
MELSEC-Q
● MELSEC-L Type J thermocouple -40 to +750°C FA-ATSVM1XTJ
● MELSEC-F
Type T thermocouple -200 to +350°C FA-ATSVM1XTT
MODBUS/TCP Type N thermocouple -200 to +1250°C FA-ATSVM1XTN
● MELSEC iQ-R
● MELSEC-Q Dummy 5 pcs FA-ATNDM5
● MELSEC-L
CC-Link master station 0 to 5V FA-ATSVM1YV05
● MELSEC iQ-R 4-channel
1 to 5V FA-ATSVM1YV15
● MELSEC iQ-F
Dedicated cable FA1-AT1B4Y1TE Voltage output
● MELSEC-Q
included (spring clamp terminal block) 0 to 10V FA-ATSVM1YV010
● MELSEC-L Analog signal
FA3-AT1□8Y-01C FA1-AT1B4Y1TB
● MELSEC-F converter (screw terminal block) + -10 to 10V FA-ATSVM1YV1010
Dedicated cable
Output model
not included
General-purpose 8-channel 0 to 20mA FA-ATSVM1YA020
FA3-AT1□8Y Current output
controller FA-ATB8YTB 4 to 20mA FA-ATSVM1YA420
(general-purpose (screw terminal block)
Ethernet) Dummy 5 pcs FA-ATNDM5
Available networks
□ = M CC-Link IE TSN, CC-Link IE Field, CC-Link IE Field Basic, SLMP (general-purpose Ethernet), MODBUS/TCP
□ = T CC-Link IE TSN, CC-Link IE Field, CC-Link IE Field Basic, SLMP (general-purpose Ethernet)
□ = C CC-Link
Analog signal converter
This converter is used to convert analog signals sent between the network interface module and temperature sensors or other devices. Channels are isolated from each other.
Spring clamp terminal type Screw terminal type
For input models, different types of analog inputs (voltage, current, distributor, thermocouple, resistance temperature detector) can be specified for each channel.
For output models, different types of analog outputs (voltage, current) can be specified for each channel.
8
Page9
■Product specifications
CC-Link IE TSN/Ethernet network interface modules
● Individual specifications
For digital signal converters (terminal modules)
Input model Output model
FA3-TH1M16XC FA3-TH1M16Y FA3-TH1M16YE
Item Item
FA3-TH1T16XC FA3-TH1T16Y FA3-TH1T16YE
Input type Positive/negative common shared type Output type Sink type Source type
Number of input points 16 Number of output points 16
OFF → ON 0.1/0.2/1/1.5/5/10/20/70ms or less*1 OFF → ON 0.5ms or less*2
Input response time Response time
ON → OFF 0.4/0.5/1/1.5/5/10/20/70ms or less*1 ON → OFF 1.5ms or less*2
Current consumption 0.11A Current consumption 0.12A
Weight 160g Weight 160g
*1: The module response time is not included. *2: The module response time is not included.
For analog signal converters
Input model Output model
FA3-AT1M8X FA3-AT1M8Y
Item Item
FA3-AT1T8X FA3-AT1T8Y
Number of analog input points 8 channels/module Number of analog output points 8 channels/module
Analog input range 1 to 5V Digital input value 0 to 16000
I/O characteristics I/O characteristics
Digital output value 0 to 16000 Analog output range 1 to 5V
Ambient temperature: Ambient temperature:
Accuracy ±0.3% (±48 digits)*3 ±0.3% (±12mV)*5
0 to 55°C 0 to 55°C
(accuracy for the Ambient temperature:
maximum digital ±0.1% (±16 digits)*3 Accuracy Ambient temperature:
±0.1% (±4mV)*5
25 ±5°C 25 ±5°C
output value)
Maximum resolution 0.25mV Maximum resolution 0.25mV
Maximum conversion speed 1ms/channel*4 Maximum conversion speed 1ms/channel*6
Current consumption 0.14A Current consumption 0.14A
Weight 160g Weight 160g
*3: The module's accuracy is not taken into account. *5: The module's accuracy is not taken into account.
*4: The module response time is not included. *6: The module response time is not included.
●Common specifications
SLMP
Item CC-Link IE TSN CC-Link IE Field CC-Link IE Field Basic MODBUS/TCP*8
(general-purpose Ethernet)
Ambient operating temperature 0 to 55°C
Ambient operating humidity 5 to 95%RH, non-condensing
Communication
1Gbps/100Mbps 1Gbps 100Mbps 100Mbps 100Mbps/10Mbps
speed
Station type Remote station Remote device station Remote station Server Remote station
Network specifications Certification class Class B - - - -
● Line/star topology
● Line/star topology
● Mixture of star and line
Topology ● Mixture of star and line Star topology Star topology Star topology
topologies
topologies
● Ring topology
Communication
RJ45 connector
External connection section
method Module power
Two-piece spring clamp terminal block
supply section
Module installation DIN rail installation or screw mounting with the supplied bracket
Ethernet cable that meets the 1000BASE-T standard
1Gbps
Category 5e or higher (double shielded, STP), straight cable
Ethernet cable that meets the 100BASE-TX standard
Communication cable 100Mbps
Category 5 or higher (double shielded, STP), straight cable
Ethernet cable that meets the 10BASE-T standard
10Mbps
Category 3 or higher (shielded, STP), straight cable
Voltage 24VDC (ripple rate within 5%) (permissible voltage: 20.4 to 28.8VDC)
Module power supply
Current Refer to the individual specifications.*7
External dimensions 105 (H) × 40 (W) × 70 (D) mm (not including the projections)
Conformity standards*9 UL, CE, UKCA, KC
*7: Both the digital signal converter and analog signal converter require a 24VDC power supply. For details on the specifications, refer to the manual of each module.
*8: MODBUS/TCP is supported by FA3-TH1M16** and FA3-AT1M8** only.
*9: Ensure compliance with required international standards also for other products used in combination.
9
Page10
CC-Link network interface module
● Individual specifications
For digital signal converters (terminal modules)
Input model Output model
Item FA3-TH1C16XC Item FA3-TH1C16Y FA3-TH1C16YE
Input type Positive/negative common shared type Output type Sink type Source type
CC-Link station type Remote I/O station CC-Link station type Remote I/O station
32 points are assigned to a station. 32 points are assigned to a station.
Number of occupied stations Number of occupied stations
(16 points are used.) (16 points are used.)
Number of input points 16 Number of output points 16
OFF → ON OFF → ON 0.5ms or less*2
Input response time 1.5ms or less*1 Response time
ON → OFF ON → OFF 1.5ms or less*2
Current consumption 90mA Current consumption 100mA 90mA
Weight 160g Weight 160g 160g
*1: The module response time is not included. *2: The module response time is not included.
For analog signal converters
Input model Output model
Item FA3-AT1C8X Item FA3-AT1C8Y
Number of analog input points 8 channels/module Number of analog output points 8 channels/module
CC-Link station type Remote device station CC-Link station type Remote device station
CC-Link version Ver.1.10 CC-Link version Ver.1.10
Number of occupied stations 2 Number of occupied stations 2
Analog input range 1 to 5V Digital input value 0 to 16000
I/O characteristics I/O characteristics
Digital output value 0 to 16000 Analog output range 1 to 5V
Ambient temperature: Ambient temperature:
Accuracy ±0.3% (±48 digits)*3 ±0.3% (±12mV)*5
0 to 55°C 0 to 55°C
(accuracy for the Ambient temperature:
maximum digital ±0.1% (±16 digits)*3 Accuracy Ambient temperature:
±0.1% (±4mV)*5
25 ±5°C 25 ±5°C
output value)
Maximum resolution 0.25mV Maximum resolution 0.25mV
Maximum conversion speed 1ms/channel*4 Maximum conversion speed 1ms/channel*6
Current consumption 120mA Current consumption 120mA
Weight 170g Weight 170g
*3: The module's accuracy is not taken into account. *5: The module's accuracy is not taken into account.
*4: The module response time is not included. *6: The module response time is not included.
● Common specifications
Item Specifications
Ambient operating temperature 0 to 55°C
Ambient operating humidity 5 to 95%RH, non-condensing
Communication speed 10M/5M/2.5M/625k/156kbps
Network specifications
Transmission path type Bus type (EIA RS485 compliant)
External connection Communication section
Two-piece spring clamp terminal block
method Module power supply section
Module installation DIN rail installation or screw mounting with the supplied bracket
Voltage 24VDC (ripple rate within 5%) (permissible voltage: 20.4 to 28.8VDC)
Module power supply
Current Refer to the individual specifications.*7
External dimensions 105 (H) × 40 (W) × 70 (D) mm (not including the projections)
Conformity standards*8 UL, CE, UKCA, KC
*7: Both the digital signal converter and analog signal converter require a 24VDC power supply. For details on the specifications, refer to the manual of each module.
*8: Ensure compliance with required international standards also for other products used in combination.
10
Page11
■External dimensions Unit: mm
CC-Link IE TSN/Ethernet
CC-Link network interface module
network interface module
40 70 40 70
(86) (88)
■Function list
CC-Link IE TSN/Ethernet network interface modules have the following functions. ○: Available, -: Not available
Digital Analog
Function Description
Input Output Input Output
Operation history recording function ○ - Records the ON/OFF history of I/O signals (100 data sets per signal).
Logging function - ○ Records the history of digital conversion values (analog input) and digital setting values
(analog output) (8000 data sets in all channels).
Maintenance information recording function ○ ○ Records the operation start date (year, month, and day), operating hours, and the
number of times relays turn ON*1.
Maintenance alarm function ○ ○ Outputs an alarm when the specified operating hours have elapsed or the number of
times relays turn ON*1. has exceeded the preset value.
*1: Number of times relays turn ON is a function available for network interface modules for digital signal converters.
■Product line
Available networks Specifications Dedicated cable Model
Input type FA3-TH1M16XC-01C
Output type (sink) Included FA3-TH1M16Y-01C
Output type (source) FA3-TH1M16YE-01C
CC-Link IE TSN For digital signal converters
Input type FA3-TH1M16XC
CC-Link IE Field Not included
Output type (sink) FA3-TH1M16Y
CC-Link IE Field Basic Use an optional cable.
Output type (source) FA3-TH1M16YE
SLMP (general-purpose Ethernet)
MODBUS/TCP Input type FA3-AT1M8X-01C
Included
Output type FA3-AT1M8Y-01C
For analog signal converters
Input type Not included FA3-AT1M8X
Output type Use an optional cable. FA3-AT1M8Y
Input type FA3-TH1T16XC-01C
Output type (sink) Included FA3-TH1T16Y-01C
Output type (source) FA3-TH1T16YE-01C
For digital signal converters
CC-Link IE TSN Input type FA3-TH1T16XC
Not included
CC-Link IE Field Output type (sink) FA3-TH1T16Y
Use an optional cable.
CC-Link IE Field Basic Output type (source) FA3-TH1T16YE
SLMP (general-purpose Ethernet) Input type FA3-AT1T8X-01C
Included
Output type FA3-AT1T8Y-01C
For analog signal converters
Input type Not included FA3-AT1T8X
Output type Use an optional cable. FA3-AT1T8Y
Input type FA3-TH1C16XC-01C
Output type (sink) Included FA3-TH1C16Y-01C
Output type (source) FA3-TH1C16YE-01C
For digital signal converters
Input type FA3-TH1C16XC
Output type (sink) Not included FA3-TH1C16Y
CC-Link Use an optional cable.
Output type (source) FA3-TH1C16YE
Input type FA3-AT1C8X-01C
Included
Output type FA3-AT1C8Y-01C
For analog signal converters
Input type Not included FA3-AT1C8X
Output type Use an optional cable. FA3-AT1C8Y
11
6 105
39.1
6 105
39.1
Page12
■Connection cables
Network interface module connection cable
Name Length Model Remarks
Dedicated cable 0.1m - Included with the product (FA3-□□-01C)
1m FA3-CB2L10MM1H20
Optional cables for CC-Link network interface modules for which
Extension cable for connection with signal converter 2m FA3-CB2L20MM1H20
dedicated cables are not provided with modules.
3m FA3-CB2L30MM1H20
CC-Link cables
CC-Link related products including CC-Link cables with or without end treatment and waterproof connectors are also available.
Name Length Model
CC-Link cable 200m*1 FA-CBL200SB
High-performance CC-Link cable 200m*1 FA-CBL200SBH
Vibration-resistant CC-Link cable for moving parts 200m*1 FA-CBL200SBZ
Ver.1.10-compatible CC-Link cable 200m*1 FA-CBL200PSBH
Ver.1.10-compatible vibration-resistant CC-Link cable for moving parts 200m*1 FA-CBL200PSBZ
Ver.1.10-compatible cold-resistant CC-Link cable 200m*1 FA-CBL200LTPSBH
Coaxial CC-Link cable with 24VDC power cable 100m*2 FA-CBL100PWSB
Ver.1.10-compatible coaxial CC-Link cable with 24VDC power cable 100m*2 FA-CBL100PWPSBH
*1: Custom lengths are not available, but a 1000-meter option is available.
*2: Custom lengths are not available, but a 500-meter option is available.
■Related catalogs ■Related leaflets
Time and Wire Saving Devices Network Devices Digital Signal Converters (Terminal Modules) Analog Signal Converters
(MEIC208E·20Y) (MEIC220E·21Y)
FAgoods FAgoods
Time and Wire Saving Devices Network Devices
General Catalog General Catalog
Time and Wire Saving Devices Time and Wire Saving Devices
Network Devices Network Devices
Products for Monitoring and Traceability Products for Monitoring and Traceability
Upgrade Tool Products Upgrade Tool Products
Products for System Maintenance Products for System Maintenance
Creating a safe and Toward the network-connected
secure control panel new age
NAGOYA ENGINEERING OFFICE 1-9, Daiko-Minami, 1-Chome, Higashi-ku, Nagoya, Aichi 461-0047 Japan
Website www.mitsubishielectricengineering.com/sales/fa/meefan/ ▶Contact US
Precautions for Choosing the Products For safe use
Mitsubishi Electric Engineering will not be held liable for damage caused ●To use the products given in this publication properly, always read the relevant manuals before beginning
by factors found not to be the cause of Mitsubishi Electric Engineering; operation.
opportunity losses or lost profits caused by faults in the Mitsubishi Electric ●The products have been manufactured as general-purpose parts for general industries, and are not designed or
Engineering products; damage, secondary damage, accident manufactured to be incorporated in a device or system used in purposes related to human life.
compensation caused by special factors unpredictable by Mitsubishi ●Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine or
passenger-carrying vehicles, consult with Mitsubishi Electric Engineering.
Electric Engineering; damages to products other than Mitsubishi Electric ●The products have been manufactured under strict quality control. However, when installing the products where major
Engineering products; and to other duties. accidents or losses could occur if the products fail, install appropriate backup or fail-safe functions in the system.
Published in June 2023
MEIC215E・214B Specifications are subject to change without notice.